background image

EKI-2701HPI-AE User Manual

6

2.1

Front Panel

On the front panel the Power over Ethernet Injector is equipped with two RJ-45 ports
and three LED indicators.

LAN port: It is an ordinary RJ-45 Ethernet port for data transmitting and receiv-
ing.

PoE port: It is an RJ-45 Ethernet port capable of supplying power over the 
Ethernet cable as well as forwarding data to powered devices.

P1 & P2: The indicators light up when their respective power inputs are active.

PoE: This LED indicator lights up while power feeding works normally.

2.2

Top View 

Designed with two power inputs, the PoE Injector allows users to supply redundant
power rating in the range of 24 to 48V.

2.3

Grounding the PoE Injector

Follow the instructions below to attach the PoE Injector to ground.

1.

On the top of the device, locate and remove the dome screw which has a 
ground symbol beside it.

2.

Attach the ground wire to the screw hole with the dome screw.

2.4

Wiring the Power Inputs

Please follow the steps below to wire power lines from the terminal block to the com-
pliant external DC power source.

1.

Before wiring, make sure the power source is disconnected.

2.

Using the wire-stripping tool, strip a short piece of insulation from the output 
wires of the DC power source.

3.

Identify the positive and negative feed positions for the terminal block connec-
tion. See the symbols printed on the panel indicating the polarities and DC input 
power range in voltage.

 

                                              

Plugs for Power 1 & Power 2

4.

Insert the exposed wires into the terminal block plugs. Only wires with insulation 
should extend from the terminal block plugs. Note that the polarities between 
the wires and the terminal block plugs must be positive to positive and negative 
to negative.

5.

Use a slotted screwdriver to tighten the captive screws.

Caution! When installing the PoE Injector, the ground connection must always be 

made first and disconnected last.

Summary of Contents for EKI-2701HPI-AE

Page 1: ...User Manual EKI 2701HPI AE Industrial IEEE 802 3at Gigabit PoE Injector...

Page 2: ...r installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our cu...

Page 3: ...charge and EMI leakage we strongly recommend the use of CE compliant industrial enclo sure products FCC Class A Note This equipment has been tested and found to comply with the limits for a Class A di...

Page 4: ...uide to Advantech s cus tomer services To ensure you get the full benefit of our services please follow the instructions below carefully Technical Support and Assistance 1 Visit the Advantech web site...

Page 5: ...ns 4 Chapter 2 Hardware Description 5 2 1 Front Panel 6 2 2 Top View 6 2 3 Grounding the PoE Injector 6 2 4 Wiring the Power Inputs 6 2 5 RJ 45 Pin Assignments 7 Chapter 3 Installation 9 3 1 DIN Rail...

Page 6: ...EKI 2701HPI AE User Manual vi...

Page 7: ...Chapter 1 1 Overview...

Page 8: ...r or other equipment supporting IEEE 802 3at The injector is typically installed near the Ethernet switch The figure below presents the example for the Power over Ethernet Injector application 1 2 Fea...

Page 9: ...UTP STP Cat 5 cable Cat 5e recom mended EIA TIA 568 100 ohm 100 m 1000Base T 4 pair UTP STP Cat 5e or above cable EIA TIA 568 100 ohm 100 m LED Power x 2 PoE x 1 Power Input 24 48VDC Power Consumption...

Page 10: ...Manual 4 1 4 Packing List 1 x Power over Ethernet Injector 1 x Wall mounting kit 1 x User Manual CD ROM 1 5 Dimensions The Power over Ethernet Injector dimensions are 36 mm W x 140 mm H x 95 mm D Fig...

Page 11: ...Chapter 2 2 Hardware Description...

Page 12: ...ymbol beside it 2 Attach the ground wire to the screw hole with the dome screw 2 4 Wiring the Power Inputs Please follow the steps below to wire power lines from the terminal block to the com pliant e...

Page 13: ...uts The table below shows the 10Base T 100Base TX MDI and MDI X port pinouts 10 100Base TX Cable Schema Straight Through Cable Schema Crossover Cable Schema Caution Use Copper Conductors Only 60 75 C...

Page 14: ...es illustrate the 10 100 1000Base T cable schema Straight Through Cable Schema Crossover Cable Schema Pin Signal name Description 1 BI_DA Bi directional pair A 2 BI_DA Bi directional pair A 3 BI_DB Bi...

Page 15: ...Chapter 3 3 Installation...

Page 16: ...to secure the DIN rail clip on the device 1 Use the screws to secure the DIN rail clip at the rear of the device 2 To remove the DIN rail clip reverse step 1 3 1 2 Hanging the PoE Injector Follow the...

Page 17: ...llow the steps below to mount the device with the wall mount plates 1 To remove the DIN Rail clip from the device unscrew the screws that secure it 2 Align the screw holes of the wall mount plates wit...

Page 18: ...EKI 2701HPI AE User Manual 12...

Page 19: ...Chapter 4 4 Troubleshooting...

Page 20: ...that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators The device can be easily monitored through LED indicators which describe common problems t...

Page 21: ...15 EKI 2701HPI AE User Manual Chapter 4 Troubleshooting...

Page 22: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...

Reviews: