Safety Instructions

Read these safety instructions carefully.

Keep this User Manual for later reference.

Disconnect this equipment from any DC outlet before cleaning. Use a damp 
cloth. Do not use liquid or spray detergents for cleaning.

For plug-in equipment, the power outlet socket must be located near the equip-
ment and must be easily accessible.

Keep this equipment away from humidity.

Put this equipment on a reliable surface during installation. Dropping it or letting 
it fall may cause damage.

The openings on the enclosure are for air convection. Protect the equipment 
from overheating. DO NOT COVER THE OPENINGS.

Make sure the voltage of the power source is correct before connecting the 
equipment to the power outlet.

Position the power cord so that people cannot step on it. Do not place anything 
over the power cord.

All cautions and warnings on the equipment should be noted.

If the equipment is not used for a long time, disconnect it from the power source 
to avoid damage by transient overvoltage.

Never pour any liquid into an opening. This may cause fire or electrical shock.

Never open the equipment. For safety reasons, the equipment should be 
opened only by qualified service personnel.

If one of the following situations arises, get the equipment checked by service 
personnel:

The power cord or plug is damaged.

Liquid has penetrated into the equipment.

The equipment has been exposed to moisture.

The equipment does not work well, or you cannot get it to work according to 
the user's manual.

The equipment has been dropped and damaged.

The equipment has obvious signs of breakage.

DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE 
STORAGE TEMPERATURE MAY GO -40°C (-40°F) ~ 75°C (167°F). THIS 
COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A 
CONTROLLED ENVIRONMENT.

The sound pressure level at the operator's position according to IEC 704-1:1982 
is no more than 70 dB (A).
DISCLAIMER: This set of instructions is given according to IEC 704-1. Advan-
tech disclaims all responsibility for the accuracy of any statements contained
herein.

Summary of Contents for EKI-1751I

Page 1: ...User Manual EKI 1751I Industrial Ethernet Extender...

Page 2: ...llation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers...

Page 3: ...can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a resi...

Page 4: ...ately 1 x Industrial Ethernet Extender 1 x DIN Rail Mounting Bracket and Screws 1 x Wall mounting Bracket Warning Warnings indicate conditions which if not observed can cause personal injury Caution C...

Page 5: ...ed for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This may cause fire or electrical shock Never open the equipment F...

Page 6: ...riod The following guidelines are also recommended Wear a grounded wrist or ankle strap and use gloves to prevent direct contact to the device before servicing the device Avoid nylon gloves or work cl...

Page 7: ...ta 4 1 5 1 24AWG Copper Wire 4 1 5 2 Coaxial Cable RG 58 5C 2V 5 Chapter 2 Hardware Description 6 2 1 Product Overview 7 2 1 1 Ping assignment for M12 Connector 7 2 2 Installing Accessory Kits 8 Chapt...

Page 8: ...es Figure 1 1 Applications 4 Figure 2 1 Product Overview 7 Figure 2 2 Ping assignment for M12 Connector 7 Figure 2 3 Installing Accessory Kits 8 Figure 5 1 3 Position DIP Switch 14 Figure 5 2 PIN 1 14...

Page 9: ...Chapter 1 1Product Introduction...

Page 10: ...nector Supporting multi mode operations EKI 1751I offers VDSL2 Band Plans Asymmetric or Symmetric SNR margin 6dB or 9dB and Master or Remote mode through a simple to use DIP switch The design fully su...

Page 11: ...es 17a and 30a Protocol Support Transparent bridging to higher layer protocols Operating Environment Operating temperature 40 C 40 F to 75 C 167 F Storage temperature 40 C 40 F to 85 C 185 F Humidity...

Page 12: ...Figure 1 1 Applications 1 5 Reference Performance Data 1 5 1 24AWG Copper Wire SNR 6dB 6dB Profile Asymmetrical Symmetrical Distance Upstream Line Rate Mbps Downstream Line Rate Mbps Upstream Line Rat...

Page 13: ...Profile Asymmetrical Symmetrical Distance Upstream Line Rate Mbps Downstream Line Rate Mbps Upstream Line Rate Mbps Downstream Line Rate Mbps 400 m 1 312 34 ft 100 100 100 100 600 m 1 968 5 ft 50 100...

Page 14: ...Chapter 2 2Hardware Description...

Page 15: ...I is a Long Reach Ethernet extender This chapter provides an overview and introduces the hardware 2 1 Product Overview Figure 2 1 Product Overview 2 1 1 Ping assignment for M12 Connector Figure 2 2 Pi...

Page 16: ...8 EKI 1751I User Manual 2 2 Installing Accessory Kits Figure 2 3 Installing Accessory Kits...

Page 17: ...Chapter 3 3LED Definitions...

Page 18: ...Power off or not installed Solid green Power 2 input connected LED per FE port 10 100Base T TX port LAN1 LAN2 LAN3 Off No connection detected or system off Solid green Secure 10 100Mbps connection Bl...

Page 19: ...Chapter 4 4Power...

Page 20: ...The device provides two terminal blocks for redundant DC power inputs Power Input Voltage is 12 to 48 VDC 10 to 60 VDC Max Power Consumption 5 Watts maximum Protection Provide over current protection...

Page 21: ...Chapter 5 53 Position DIP Switch...

Page 22: ...Symmetric Support the band plan G 997 and provide the symmetric transmis sion on both downstream and upstream Asymmetric Provides hightest line rate in short range in asymmetric mode 5 2 General Prot...

Page 23: ...ion Restricted Access Location This device is intended for installation only in restricted access locations as defined where both these conditions apply Access is through the use of a lock or tool and...

Page 24: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...

Reviews: