14
EKI-1751I User Manual
The device is equipped with DIP Switch selection which allows users to select the
parameters in order to meet varying applications needs.
Figure 5.1 3-Position DIP Switch
5.1
Band Plan
Figure 5.2 PIN 1
Symmetric: Support the band plan G.997 and provide the symmetric transmis-
sion on both downstream and upstream.
Asymmetric: Provides hightest line rate in short range in asymmetric mode.
5.2
General Protection
Figure 5.3 PIN 2
9 dB: Better channel noise protection with SNR up to 9 dB.
6 dB: Origial channel noise protection with 6 dB SNR.
Option
Pin 1
Pin 2
Pin 3
Profile
SNR
Master / Remote
OFF
Symmetric
9dB
OT
ON
Asymmetric
6dB