INTEGRATED UPS AND BATTERY PACK (OPTIONAL)
The DLT-V72 is optionally available with an integrated uninterrupted poser supply
(short: UPS). The lithium-ion battery pack (short: battery pack) of this UPS is located in
the battery pocket up top on the device:
WARNING
Personal injury due to short-circuit, fire, chemical burns, toxic substances.
DLT-V72 devices with integrated UPS contain battery packs. These can ignite if handled
or stored improperly (risk of fire), cause chemical burns or release toxic substances.
−
Be careful when handling battery packs.
−
Do not damage the battery packs, drill through them, drop them or allow them to be
crushed.
−
Do not allow water or other liquids to come into contact with the device (exercise
particular caution with corrosive liquids).
−
Do not allow it to come into contact with fire.
8.1
Battery pack: Environmental conditions / Technical data
Battery pack 2000 mAh: P/N: DL-BTRG79461700
Operating temperature
-30 to +50 °C
Maximum output power 40 W
Battery voltage
7,2 V
Bridging time
Typically 20 min (if the battery pack is fully charged)
Charging time
4 h (fully recharge a discharged battery pack)