iMcV-LIM
6
-
If another type of module is installed into the same slot in a chassis,
the iMcV-LIM clears the memory of the previous configuration for that
slot; the settings of a new module are adopted and stored in the
iMcV-LIM
The SNMP Write Lock switch does not impact any iMcV module or iMcV
module with Configuration Control. Removing and installing a new SNMP
Management Module will no longer impact these modules either. However, if
there is a mixture of iMcV modules with and without Configuration Control, the
Write Lock Switch and a new SNMP Management Module must be taken into
consideration.
If the command cleandb is applied to an SNMP Management Module, all the
settings for the modules will be removed, but the Configuration Control
modules will still be based on the last change made, while those without
Configuration Control will be set to their default settings.
NOTE
:
If the end user has a mixture of standard iMcV modules as well as Configuration
Control iMcV modules, it is important to understand how SNMP and DIP Switches will
impact the cards depending on their capability. Standard iMcV modules cannot be
upgraded to Configuration Control capability, so it is strongly recommended to set the DIP
Switches on the modules and then configure them via software to match the same settings.
UNMANAGED MODULES
Before installing, configure the iMcV-LIM modules for desired features. The
table below indicates the available features and settings for the iMcV-LIM
modules.
After configuring the DIP Switches for the desired settings, install the module
and connect the appropriate cables (refer to Installing an iMcV-LIM section for
more information).