iMcV-LIM 

 

 

If another type of module is installed into the same slot in a chassis, 

the iMcV-LIM clears the memory of the previous configuration for that 

slot; the settings of a new module are adopted and stored in the 

iMcV-LIM 

 

The SNMP Write Lock switch does not impact any iMcV module or iMcV 

module with Configuration Control. Removing and installing a new SNMP 

Management Module will no longer impact these modules either. However, if 

there is a mixture of iMcV modules with and without Configuration Control, the 

Write Lock Switch and a new SNMP Management Module must be taken into 

consideration. 
If the command cleandb is applied to an SNMP Management Module, all the 

settings for the modules will be removed, but the Configuration Control 

modules will still be based on the last change made, while those without 

Configuration Control will be set to their default settings. 

NOTE

If the end user has a mixture of standard iMcV modules as well as Configuration 

Control iMcV modules, it is important to understand how SNMP and DIP Switches will 

impact the cards depending on their capability. Standard iMcV modules cannot be 

upgraded to Configuration Control capability, so it is strongly recommended to set the DIP 

Switches on the modules and then configure them via software to match the same settings.

 

UNMANAGED MODULES 

Before installing, configure the iMcV-LIM modules for desired features. The 

table below indicates the available features and settings for the iMcV-LIM 

modules.  
After configuring the DIP Switches for the desired settings, install the module 

and connect the appropriate cables (refer to Installing an iMcV-LIM section for 

more information). 

Summary of Contents for B+B SmartWorx iMcV-LIM

Page 1: ...iMcV LIM with LFPT ConfigControl USER MANUAL...

Page 2: ...707 Dayton Road Ottawa IL 61350 USA Phone 1 815 433 5100 Fax 1 815 433 5105 Advantech B B SmartWorx Europe Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 ww...

Page 3: ...9 FiberAlert and Far End Fault 11 Auto Negotiation on iMcV LIM 12 AutoCross Feature for Twisted pair Connection 13 LED Operation 14 Troubleshooting Installation 15 Specifications 16 B B SmartWorx Tech...

Page 4: ...require items that are sold separately available from B B SmartWorx CONFIGURATION The iMcV LIM has user configurable features e g FiberAlert FA TX LinkLoss TXLL FX LinkLoss FXLL Link Fault Pass Throu...

Page 5: ...ess of how that configuration was implemented via DIP Switch settings or SNMP Historically SNMP would override DIP Switch settings If changes are made via DIP Switch settings then hardware settings de...

Page 6: ...uration Control modules will still be based on the last change made while those without Configuration Control will be set to their default settings NOTE If the end user has a mixture of standard iMcV...

Page 7: ...otiation AN ON 2 Far End Fault FEF OFF 3 FX LinkLoss FXLL OFF 4 TX LinkLoss TXLL OFF 5 FiberAlert FA OFF 6 Factory Default OFF 7 Factory Default OFF 8 Factory Default OFF NOTE Best Practices When poss...

Page 8: ...guration Control DIP Switch on S1 Feature Default Setting 1 Auto Negotiation AN ON 2 Far End Fault FEF OFF 3 FX LinkLoss FXLL OFF 4 TX LinkLoss TXLL OFF 5 FiberAlert FA OFF 6 Factory Default OFF 7 Ena...

Page 9: ...link pulses are reaching the other end The combination of FiberAlert and LinkLoss allows this information to be obtained even when physical access to a remote device and its link integrity LED is not...

Page 10: ...h FX and TX LinkLoss on both modules This feature allows either end of the conversion to detect a link fault occurring at the other end of the media conversion chain Regardless if there is a break in...

Page 11: ...cal site administrator is notified of a fault and can quickly determine where a cable fault is located WARNING Enable FiberAlert at the remote side of a media conversion only Enabling it on both sides...

Page 12: ...n there is a fault in one direction of the fiber it acts on the fiber in the opposite direction But unlike FEF FA sends no signal Because of this FA can not be enabled on both ends If it is enabled an...

Page 13: ...ure Auto Negotiation on an iMcV LIM by adjusting the DIP Switch setting for unmanaged modules or via the management software Refer to the DIP Switch table for switch location and settings AUTOCROSS FE...

Page 14: ...tware is disabled on the TX port FA Glows green when FiberAlert is enabled Blinks green when active FXLL Glows green when FX LinkLoss is enabled on the port Blinks when a fault occurs on the fiber por...

Page 15: ...iMcV LIM to the twisted pair device with a twisted pair cable 2 Loop a single strand of fiber from the transmit port to the receive port of the iMcV LIM 3 Verify that both the twisted pair and the fib...

Page 16: ...iMcV LIM 16 SPECIFICATIONS Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 25 to 70 C 13 to 158 F Humidity 5 to 95 non condensing DC Input iMcV LIM w LFPT 0 80 A 5V...

Page 17: ...ay cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interf...

Page 18: ...e a qualified service technician and use tools and techniques that conform to accepted industry practices FIBER OPTIC CLEANING GUIDELINES Fiber Optic transmitters and receivers are extremely susceptib...

Page 19: ...r local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information abou...

Reviews: