Advantech B+B SmartWorx iMcV-LIM User Manual Download Page 17

iMcV-LIM 

 

17 

 

 

B+B SMARTWORX TECHNICAL SUPPORT 

 
USA/Canada: 

1 (800) 346-3119 (Ottawa IL USA)

 

Europe: 

+353 91 792444 (Ireland / Europe)

  

Email: 

[email protected]

 

Web: 

www.advantech-bb.com

 

 

 

 

STATEMENTS,  PRECAUTIONS,  GUIDELINES,  REGULATORY 

 

FCC  RADIO  FREQUENCY  INTERFERENCE  STATEMENT 

This equipment has been tested and found to comply with the limits for a 

Class A computing device, pursuant to Part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference 

when the equipment is operated in a commercial environment. This equipment 

generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a 

residential area is likely to cause harmful interference in which the user will be 

required to correct the interference at his own expense. 
Any changes or modifications not expressly approved by the manufacturer 

could void the user’s authority to operate the equipment. 
The use of non-shielded I/O cables may not guarantee compliance with FCC 

RFI limits. This digital apparatus does not exceed the Class A limits for radio 

noise emission from digital apparatus set out in the Radio Interference 

Regulation of the Canadian Department of Communications. 
Le présent appareil numérique n’émet pas de bruits radioélectriques 

dépassant les limites applicables aux appareils numériques de classe A 

prescrites dans le Règlement sur le brouillage radioélectrique publié par le 

ministère des Communications du Canada. 

 

 

Summary of Contents for B+B SmartWorx iMcV-LIM

Page 1: ...iMcV LIM with LFPT ConfigControl USER MANUAL...

Page 2: ...707 Dayton Road Ottawa IL 61350 USA Phone 1 815 433 5100 Fax 1 815 433 5105 Advantech B B SmartWorx Europe Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 ww...

Page 3: ...9 FiberAlert and Far End Fault 11 Auto Negotiation on iMcV LIM 12 AutoCross Feature for Twisted pair Connection 13 LED Operation 14 Troubleshooting Installation 15 Specifications 16 B B SmartWorx Tech...

Page 4: ...require items that are sold separately available from B B SmartWorx CONFIGURATION The iMcV LIM has user configurable features e g FiberAlert FA TX LinkLoss TXLL FX LinkLoss FXLL Link Fault Pass Throu...

Page 5: ...ess of how that configuration was implemented via DIP Switch settings or SNMP Historically SNMP would override DIP Switch settings If changes are made via DIP Switch settings then hardware settings de...

Page 6: ...uration Control modules will still be based on the last change made while those without Configuration Control will be set to their default settings NOTE If the end user has a mixture of standard iMcV...

Page 7: ...otiation AN ON 2 Far End Fault FEF OFF 3 FX LinkLoss FXLL OFF 4 TX LinkLoss TXLL OFF 5 FiberAlert FA OFF 6 Factory Default OFF 7 Factory Default OFF 8 Factory Default OFF NOTE Best Practices When poss...

Page 8: ...guration Control DIP Switch on S1 Feature Default Setting 1 Auto Negotiation AN ON 2 Far End Fault FEF OFF 3 FX LinkLoss FXLL OFF 4 TX LinkLoss TXLL OFF 5 FiberAlert FA OFF 6 Factory Default OFF 7 Ena...

Page 9: ...link pulses are reaching the other end The combination of FiberAlert and LinkLoss allows this information to be obtained even when physical access to a remote device and its link integrity LED is not...

Page 10: ...h FX and TX LinkLoss on both modules This feature allows either end of the conversion to detect a link fault occurring at the other end of the media conversion chain Regardless if there is a break in...

Page 11: ...cal site administrator is notified of a fault and can quickly determine where a cable fault is located WARNING Enable FiberAlert at the remote side of a media conversion only Enabling it on both sides...

Page 12: ...n there is a fault in one direction of the fiber it acts on the fiber in the opposite direction But unlike FEF FA sends no signal Because of this FA can not be enabled on both ends If it is enabled an...

Page 13: ...ure Auto Negotiation on an iMcV LIM by adjusting the DIP Switch setting for unmanaged modules or via the management software Refer to the DIP Switch table for switch location and settings AUTOCROSS FE...

Page 14: ...tware is disabled on the TX port FA Glows green when FiberAlert is enabled Blinks green when active FXLL Glows green when FX LinkLoss is enabled on the port Blinks when a fault occurs on the fiber por...

Page 15: ...iMcV LIM to the twisted pair device with a twisted pair cable 2 Loop a single strand of fiber from the transmit port to the receive port of the iMcV LIM 3 Verify that both the twisted pair and the fib...

Page 16: ...iMcV LIM 16 SPECIFICATIONS Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 25 to 70 C 13 to 158 F Humidity 5 to 95 non condensing DC Input iMcV LIM w LFPT 0 80 A 5V...

Page 17: ...ay cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interf...

Page 18: ...e a qualified service technician and use tools and techniques that conform to accepted industry practices FIBER OPTIC CLEANING GUIDELINES Fiber Optic transmitters and receivers are extremely susceptib...

Page 19: ...r local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information abou...