Before cleaning the NDcoders, first disconnect the power supply from the
NDcoder, and then disconnect all other cables.
Use only a moist, soft, and lint-free cloth. Avoid abrasive cloths, towels, paper towels, and similar
items that might cause damage to the aluminum housing. Ensure that no moisture enters any
opening and only use mild cleaning agents.
The enclosure of AVAS-212 is made of aluminum that can help heat dissipation, since the device does
not have cooling fans. Please provide regular maintenance to remove any dirt or dust on the enclosure
that can reduce the cooling capacity of the enclosure.
4.1.1
Cleaning and Maintenance Instructions
4.1.2
NDcoder Specifications
Electrical:
Operating voltage PSU
100~240VAC
AC voltage
Operating voltage
NDcoder
12VDC
DC voltage
Power consumption
2A@12VDC
Maximum
Reverse battery
protection
Yes
No damage to the unit
Fuse
2.5A
Slow blow, non-resettable
Mechanical:
Size
176.50x220x44mm
Weight
1.3kg
Environmental:
Operation temperature
0 °C to +40 °C
Non-condensing
Storage temperature
-10° to 50°C
Non-condensing