AWMA-Kx500-BTE
10.3 RESPONSE TO COMMANDS FROM SLAVE TO MASTER
For command 0x2A (request condition status) the response is given in the following table.
TABLE 14
: CONDITION STATUS RESPONSE
Bit # 2
nd
byte
3
rd
byte
4
th
byte
5
th
byte
6
th
byte
0
Tx status 1-ON, 0-FF
0
1
1- Tx Sum Alarm
1 – Auto; 0 - Manual
2
0
1 – Unknown command
3
0
4
0
5
0
6
0
7
Output
level
MS byte
Output
level
LS byte
Internal
Communication
Status
(see NOTES)
Power Class for
P1dB
(power in dBW)
5 bits
From 30dBm – step
1dB
0 dBW = 30 dBm
1 dBW = 31 dBm
…
23 dBW = 53 dBm
0
NOTES:
4th byte – Internal Communication Status is: 1 – for no communication, 0 – for
communication O/K.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Neighbor HPAL HPAR
Combined
DPM
Driver N/U
Input
Module
(IM)
Digital Power
Monitor
Module
(DPM)
TABLE 15
: READ IDENTIFICATION RESPONSE
Bit #
2
nd
byte
3
rd
byte
4
th
byte
5
th
byte
6
th
byte
0 0
0
0
1 0
0
0
2
1 – PA (Driver)
0
0
3 0
0
0
4
1 – HPAL (Left)
0
0
5
1 – HPAR (Right)
0 0
6 0
0
0
7
1 – Input Module
0
0x30 – Single Band
SSPA
0
Software
Version
number
0xXX