3
II.
Model Numbering and General Specifications
BUILD A MODEL
GF
- __ __ __ __ __ __ - __ __
TANK SELECTION
0 = No tank
1 = 55 gallon poly
2 = 100 gallon poly
3 = 30 gallon poly
7 = 150 gallon poly
STAND SELECTION
A = Powder Coated steel stand
B = Powder Coated steel stand w/ mixer bracket
C = Tank top mount (no tank included)
D = Portable stand with built in rollers
PUMP SELECTION
*
Dual pump sys. require 2 pump selections (i.e., -11)
0 = No pump
1 = 1.5 gpm at 100 PSI; 1/3 hp
2 = 3.75 gpm at 100 PSI; 1/2 hp
3 = 6.1 gpm at 60 PSI; 1/3 hp
4 = 9.9 gpm at 60 PSI; 1.5 hp
5 = 30 gpd at 100 PSI; solenoid driven
PUMP CONFIGURATION
A = Standard configuration
B = Alternating pumps for single loops
(requires 2 pump selections)
C = Pump plumbed for transfer duty into tank
LOOP SELECTION
*
Dual loop sys. require 2 loop selections (i.e., -11)
0 = No loop
1 = Sch 80 PVC loop; 100 PSI max; 100
°
F max
2 = Copper/brass loop; 100 PSI max; 180
°
F max
3 = Carbon steel loop; 100 PSI max
CONTROL SELECTION
A =
Digital controller
w/ 0-100 PSI pressure transducer
for 30 gal & + sizes
D = Pressure transducer, level wand and pump
starter relay for use with separately ordered
MegaTron or XS with 4-20mA input ability
F = Digital controller for dual loops with two sensors
OPTIONS
1 = 240V
2 = 4-20mA output of pressure on digital controller
3 = Solenoid valve for pressure relief on digital units
4 = 30-50 PSI pressure switch for analog units
5 = Position backcheck to use tank for expansion
H = 1/4” PVC pipe instead of pump suction tubing
M = Mixer controls (order mixer separate)
Y = ETL approval (only on units with controller option D)
Most units include poly tank and stand, low
level switch with audible alarm (100db) with
silence switch, dry contact alarm, pressure
relief valve and plumbing assembly with
pressure gauge.
Digital
models display the actual loop
pressure and
allow for user settable control
points from a pressure sensor rated for 5-100
psi (0.3-6.9 bar). 16 character LCD, backlit
display. EPROM memory.