2.3  Level 1 Menu Functions 

The following table gives a list of the Level 1 Menu Functions and a brief description for each function. 

Menu Option 

Sub Menu / 
Item 

Comments / Description 

VIEW 

FAULTS 

View any current fault conditions recorded. 

DISABLES 

View any current disablement conditions. 

WARNINGS 

View any current extinguishant warnings conditions. 

LOG 

View the history log. 

SW VERSIONS 

View the software version installed in the extinguishant control panel 
and in remote status indicator panels. 

LED TEST 

-- 

Disable Zone, Sounder, Input and Output circuits and disable 
functions. Enable any current disablement conditions 

EXIT  

-- 

Return to the normal status display. 

 

2.3.1 

Navigating through Level 1 Menus 

Press the 

 button to select the Menu Options 

When the menu is displayed, use the 



 buttons to highlight the required menu 

option and then press the 

 button to select it. 

Press the 

 button from within a menu option to return to the previous menu. 

 

The display will revert to the status mode display after 60 seconds on no activity 

(15 seconds in a fire alarm condition). Press the 

 button again to return to the menu option.  

2.3.2 

View 

On selection, the current status of any Faults, Disablements and Warnings along with the history Log can be 
shown. 

[View Menu] 

FAULTS             

.

 

DISABLES 
WARNINGS 
SW VERSIONS 
EXIT 
 

Press the 



 buttons to scroll through the list and press the 

 

button to select the required view option. 

 

 

[Fault Status] 
 
 Nothing to Report 
 
 
 
 

If there are no conditions present, the 

display will show “Nothing to 

Report”. 

 

2.3.2.1  Faults 

[Fault Status] 
       1 of 3 

DETECTION ZONE 1   

.

 

>SHORT CIRCUIT     

.  

DETECTION ZONE 2 
>OPEN CIRCUIT 
 

If there are fault conditions present, the display will show the 
number of conditions and a list of the fault conditions. 

Press the 



 buttons to scroll through the list of faults. 

Press the 

 button to return to the previous menu. 

[Level 1 Menu] 

VIEW               

.

 

LED TEST 
EXIT 
 
 

Summary of Contents for ExGo Series

Page 1: ...www advancedco com Remote Status Indicators Installation and Commissioning The operation and functions described in this manual are available from Software Version Ex 3000 V2 05C onwards...

Page 2: ...f 1 Relay Outputs Optional 2x rated at 1A 30VAC DC max 10mA 5V min programmable requires EXP 007 Key Switches 1x programmable Optional Fitted Optional Fitted Manual Release No No Yes Yes External Inpu...

Page 3: ...Abort Condition 10 2 2 5 Fault Condition 10 2 2 6 Warning Condition 10 2 3 LEVEL 1 MENU FUNCTIONS 11 2 3 1 Navigating through Level 1 Menus 11 2 3 2 View 11 2 3 2 1 Faults 11 2 3 2 2 Disables 12 2 3...

Page 4: ...se of the Ex 3000 Series Remote Status Indicating Panels The Ex 3020 is an RSI with Liquid Crystal Display and LED Indicators The Ex 3021 is an RSI with Liquid Crystal Display LED Indicators and Mode...

Page 5: ...3030 but is without the Manual Release function 2 1 1 1 Display The LCD along with the LED Indicators shows the operating status of the system Examples of the information presented is shown below Nor...

Page 6: ...anel has detected the folw of the extinguishant released TIMER HELD Yellow Indicates that the imminent release of extinguishant is temproraily suspended ABORTED Yellow Indicates that the imminent rele...

Page 7: ...ions of these are programmable and the installer will have inserted a label to indicate their use Typical uses are AUTO MANUAL MANUAL ONLY Selection EXTRACT OVERRIDE Depending on the key switch mechan...

Page 8: ...nel press the RESET button on the control panel NOTE If the programming of the panel is such that the release condition is immediately invoked on detection of a single fire alarm then the display will...

Page 9: ...n on the control panel Section 4 12 2 Reset of the Activated Condition Release Signal NOTE In accordance with EN 12094 1 the ECD shall not permit a reset until either the RELEASED condition has been e...

Page 10: ...UNAFFECTED NOTE The fault condition is non latching except System Fault and the indications will automatically be cleared when the fault is remedied Press the RESET key to clear a System Fault NOTE If...

Page 11: ...u option and then press the button to select it Press the button from within a menu option to return to the previous menu The display will revert to the status mode display after 60 seconds on no acti...

Page 12: ...e warning conditions Press the buttons to scroll through the list of warnings Press the button to return to the previous menu 2 3 2 4 Software Versions The display shows the revision of software insta...

Page 13: ...Indicator ZONE 2 ZONE 3 SYSTEM FAULT MODE SUPPLY INPUTS 485 IN 485 OUT USB REBOOT SWITCH CONTRAST ADJUST RUN PROG COVER FIXING SCREWS The panel comprises a back box and cover chassis assembly The chas...

Page 14: ...n the diagram below Remove the chassis before installing the enclosure retain in a safe place Ensure that there is sufficient space to allow the cover to be removed opened when the panel is finally mo...

Page 15: ...a Safety Extra Low Voltage SELV supply Connect the 24V DC supply feed input to the SUPPLY 24V and 0V terminals on the interface card Use cables of sufficient size to ensure that the power input voltag...

Page 16: ...t conditions see typical arrangement below EOL 6800 Maximum line impedance 50 Connect to volt free switches relay contacts only MANUAL ONLY AUTO MANUAL DISABLED FAULT TIMER HELD ABORTED RELEASE IMMINE...

Page 17: ...description into the pocket in the fascia label Plug the connector into the respective connector on the card Key Switch assemblies are available in both trapped and non trapped versions The function...

Page 18: ...www advancedco com 18 This page is intentionally left blank...

Page 19: ...www advancedco com 19 USER NOTES...

Page 20: ...ystem Emergency Abort Device Activation of Alarm Devices with Different Signals Response delay activated condition maximum 3s Response delay triggering of outputs maximum 1s EN54 2 1997 A1 Control and...

Reviews: