CLASS B EXTINGUISHER
Storage Color Code: Red (Flammable)
-----------------------------------------------------------------------------------------------------------
Potential Health Effects
----------------------------------
Inhalation:
Exposure may cause irritation to the mucous membranes of the upper respiratory tract. Prolonged exposures
to high concentrations may cause drowsiness, loss of appetite and inability to concentrate.
Ingestion:
Cause headaches, gastritis, intoxication, blindness and, in acute cases, death.
Skin Contact:
Causes skin irritation, cracking or flaking due to dehydration and defatting action.
Eye Contact:
Can cause eye irritation. Splashes may cause temporary pain and blurred vision.
Chronic Exposure:
Prolonged skin contact causes drying and cracking of skin. May affect the nervous system. May affect liver,
blood, reproductive system. Continued ingestion of small amounts could result in blindness.
Aggravation of Pre-existing Conditions:
Persons with pre-existing skin disorders or eye problems or impaired liver or kidney function may be more
susceptible to the effects of the substance.
4. First Aid Measures
Inhalation:
Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a
physician.
Ingestion:
Induce vomiting immediately as directed by medical personnel. Never give anything by mouth to an
unconscious person.
Skin Contact:
Remove any contaminated clothing. Wash skin with soap or mild detergent and water for at least 15 minutes.
Get medical attention if irritation develops or persists.
Eye Contact:
Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper eyelids
occasionally. Get medical attention immediately.
5. Fire Fighting Measures
Fire:
Flash point: 13C (55F) CC
Autoignition temperature: 422C (792F)
Flammable limits in air % by volume:
lel: 3.3; uel: 19
Flammable liquid and vapor!
Dangerous fire hazard when exposed to heat or flame.
Explosion:
Above flash point, vapor-air mixtures are explosive within flammable limits noted above. Vapors can flow
along surfaces to distant ignition source and flash back. Sealed containers may rupture when heated.
Sensitive to static discharge.
Fire Extinguishing Media:
Water spray, dry chemical, alcohol foam, or carbon dioxide. Water may be ineffective.
Special Information:
In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus
with full facepiece operated in the pressure demand or other positive pressure mode. Water spray can be
used to extinguish fires and cool fire-exposed containers. Water may be used to flush spills away from
exposures and to dilute spills to non-flammable mixtures.