Motus Reference Manual
Page 141 of 146
Version 1.1
29/11/2019
6
3D calibration in progress
7
2D calibration error: excessive roll
8
2D calibration error: excessive pitch
9
Calibration error: sensor over range event
10
Calibration error: time-out
11
Calibration error: system error
12
Calibration error: interference error
Table 108: Magnetic calibration status
16.10.11
Odometer Configuration Packet
Odometer Configuration Packet
Packet ID
192
Length
8
Field
#
Bytes
Offset
Data
Type
Size
Description
1
0
u8
1
Permanent
2
1
u8
1
Automatic pulse measurement active
3
2
u8
2
Reserved (set to zero)
4
4
fp32
4
Pulse length (m)
Table 109: Odometer configuration packet
16.10.12
Set Zero Orientation Alignment Packet
This packet was modified as of firmware version 1.0 for code safety certification.
Previously it was 1 byte long with no verification sequence.
Set Zero Orientation Alignment Packet
Packet ID
193
Length
5
Field
#
Bytes
Offset
Data
Type
Size
Description
1
0
u8
1
Permanent
2
1
u32
4
Verification sequence (set to 0x9A4E8055)
Table 110: Set zero orientation alignment packet
16.10.13
Reference Point Offsets Packet
The reference point offsets packet can be used to adjust the measurement point that
all data is referenced to. By default all the values of this packet are zero and the