Modes of Operation
Continuous
Each channel is capable of up to 1A output in
standard mode
. Continuous mode
is not possible in
sequence mode
; in sequence mode, DC can be simulated by
using long pulse widths.
Note: Depending on the load and power dissipation, not all channels may
operate at 1A simultaneous. The controller must maintain a safe power
dissipation, so channel currents may be throttled.
Pulsed
Pulsed mode illumination is triggered by an external signal.
Pulse widths and delay are available from 10 to 4,290,000000 microseconds
and can be applied independently to any channel.
Sequence
Channels settings are organized into
events
. The event could be considered a
pre-set, or recipe, that stores the behavior when a trigger is received.
Programming multiple
events
allows the controller to sequence through pre-
determined recipes. Each external trigger edge will advance the sequence to the