7.2.4. 

Memory Card – ATMEL AT88C1608 

7.2.4.1. 

SELECT_CARD_TYPE 

This command powers down and up the selected card that is inserted in the card reader and performs 
a card reset. It will also select the page size to be 16-byte page write. 

Note:  This command can only be used after the logical smart card reader communication has been 
established  using the SCardConnect( ) API. For details of SCardConnect( ) API, please refer to 
PC/SC specifications.

 

Command Format (

abData

 field in the 

PC_to_RDR_XfrBlock

Pseudo-APDU 

CLA 

INS 

P1 

P2 

Lc 

Card Type 

FFh 

A4h 

00h 

00h 

01h 

04h 

 

Response Data Format (

abData

 field in the 

RDR_to_PC_DataBlock

SW1 

SW2 

 

 

Where: 

SW1 SW2

  = 90 00h if no error 

 

7.2.4.2. 

READ_MEMORY_CARD 

Command Format (

abData

 field in the 

PC_to_RDR_XfrBlock

Pseudo-APDU 

CLA 

INS 

Zone Address 

Byte Address 

MEM_L 

FFh 

 

 

 

 

Where: 

INS

  

 

 

 

= B0h for reading user zone 

= B1h for reading configuration zone or reading fuse 

Zone Address

   

= 0000 0A

10

A

9

A

8

b where A

10

 is the MSB of zone address 

= don’t care for reading fuse 

Byte Address

 

= A

7

A

6

A

5

A

4

  A

3

A

2

A

1

A

0

b is the memory address location of the memory 

card 

= 1000 0000b for reading fuse 

MEM_L

  

 

 

Length of data to be read from the memory card 

Response Data Format (

abData

 field in the 

RDR_to_PC_DataBlock

BYTE 1 

… 

… 

BYTE N 

SW1 

SW2 

 

 

 

 

 

 

Where: 

BYTE x

  

Data read from memory card 

SW1 SW2 

= 90 00h if no error 

Summary of Contents for ACR3901T-W1

Page 1: ...Subject to change without prior notice info acs com hk www acs com hk Reference Manual V1 02 ACR3901T W1 ACS Secure Bluetooth Contact Card Reader...

Page 2: ...g API Updated Section 6 1 3 Authentication Updated Section 6 1 5 Bluetooth Communication Protocol Updated Section 6 1 5 1 Card Power On Updated Section 6 1 5 2 Card Power Off Updated Section 6 1 5 3 G...

Page 3: ...ds 12 5 5 5 Card Tearing Protection 12 6 0 Software Design 13 6 1 Bluetooth Communication Protocol 13 6 1 1 Bluetooth Connection Program Flow 13 6 1 2 Profile Selection 14 6 1 3 Authentication 16 6 1...

Page 4: ...Memory Card SLE 4404 89 7 2 9 Memory Card AT88SC101 AT88SC102 AT88SC1003 93 Appendix A Error Codes 100 List of Figures Figure 1 ACR3901T W1 Architecture 8 Figure 2 Bluetooth Connection Flow 13 Figure...

Page 5: ...00 Universal Serial Bus Common Class Specification 1 0 December 16 1997 Universal Serial Bus Device Class Smart Card CCID Specification for Integrated Circuit s Cards Interface Devices Revision 1 1 Ap...

Page 6: ...PS Protocol and Parameters Selection Features Short Circuit Protection Supports AES 128 encryption algorithm Application Programming Interface o Supports PC SC o Supports CT API through wrapper on top...

Page 7: ...the default parameters F 372 D 1 For the meaning of the aforementioned parameters please refer to ISO 7816 3 3 2 Memory based Smart Cards ACR3901T W1 works with several memory based smart cards such a...

Page 8: ...Page 8 of 100 4 0 System Block Diagram Figure 1 ACR3901T W1 Architecture ACR3901T W1 Battery Charge Management IC MCU Bluetooth External devices e g computer or mobile phone LEDs SAM card Rechargeable...

Page 9: ...ry life The battery life is dependent on the usage of the device Below is an estimate of the battery life depending on the various work conditions Mode Estimated Battery Life Working Mode 4 days 1 Sta...

Page 10: ...on 1 VBUS 5 V power supply for the reader 2 D Differential signal transmits data between ACR3901T W1 and computer 3 D Differential signal transmits data between ACR3901T W1 and computer 4 GND Referenc...

Page 11: ...ere Red LED Battery status Blue LED Card and reader status under Bluetooth mode Green LED Card and reader status under USB mode Color LED Activity Status Red On The battery is charging will turn OFF a...

Page 12: ...cludes both the memory cards and MCU based cards For MCU based cards the reader allows to select the preferred protocol T 0 or T 1 However this selection is only accepted and carried out by the reader...

Page 13: ...Protocol 6 1 1 Bluetooth Connection Program Flow The program flow of a Bluetooth connection is shown below Figure 2 Bluetooth Connection Flow Yes No Bluetooth Start Reset Power up Successful Connecti...

Page 14: ...fy the paired device through a specific pipe To simplify the battery levels are divided into three groups Below is a table summarizing the battery level and its corresponding return value Status Volta...

Page 15: ...UMBER_OF_PIPES 10 define PIPE_GAP_DEVICE_NAME_SET is used to change the device name at runtime by the application controller So that in Bluetooth mode the advertising name will be in the format of ACR...

Page 16: ...bridging device for simplicity and better illustration Figure 4 Authentication Procedure After successful authentication a 16 byte Session Key is generated in both ACR3901T W1 and the data server Def...

Page 17: ...ntication was introduced to avoid man in the middle attacks through the Bluetooth communication channel After a successful mutual authentication the Bluetooth Frame Format in Table 6 will be encrypted...

Page 18: ...thenticated Paired device Peripheral Commands 70h Connected Authenticated Paired device SPH_to_RDR_ReqAuth 71h Connected Authenticated Paired device SPH_to_RDR_AuthRsp Table 8 Command Code Summary Com...

Page 19: ...r of extra bytes starting from the next field for this message and is expressed in two bytes long and LEN1 is LSB while LEN2 is MS 3 N byte ATR N Card Answer To Reset 3 N CSUM wChecksum 1 CSUM means t...

Page 20: ...d Size Value Description 0 bMessageType 1 13h 1 LEN1 LEN2 wLength 2 0100h Number of extra bytes starting from the next field for this message and is expressed in two bytes long and LEN1 is LSB while L...

Page 21: ...XOR values of all bytes in the command Response Data Format Error Offset Field Size Value Description 0 bMessageType 1 94h 1 LEN1 LEN2 wLength 2 0200h Number of extra bytes starting from the next fie...

Page 22: ...ssageType 1 11h 1 LEN1 LEN2 wLength 2 Number of extra bytes starting from the next field for this message and is expressed in two bytes long and LEN1 is LSB while LEN2 is MSB 3 APDU Response N APDU Fo...

Page 23: ...1 is LSB while LEN2 is MSB Maximum length is 263 3 Data Param 1 Parameter Short APDU level 00h default Extended APDU level 00h the command APDU begins and ends with this command 01h the command APDU b...

Page 24: ...and ends the response APDU 03h this Data field continues the response APDU and another block is to follow 10h empty Data field continuation of the command APDU is expected in the next Command 4 APDU...

Page 25: ...eans the XOR values of all bytes in the command Example Sends 600 bytes data to the card 1 Command 67 07 01 01 261 bytes data checksum Response 17 02 00 10 checksum 2 Command 67 07 01 03 261 bytes dat...

Page 26: ...m 1 CSUM means the XOR values of all bytes in the command Response Data Format Offset Field Size Value Description 0 bMessageType 1 15h Escape Response Header 1 LEN1 LEN2 wLength 2 Number of extra byt...

Page 27: ...l info acs com hk Version 1 02 www acs com hk Page 27 of 100 Offset Field Size Value Description 3 Error Code bErrorCode 1 Error Code Refer to Appendix A 4 CSUM wChecksum 1 CSUM means the XOR values o...

Page 28: ...ucture for protocol T 0 01h Structure for protocol T 1 4 ProtocolDataStructure N Protocol Data Structure 4 N CSUM wChecksum 1 CSUM means the XOR values of all bytes in the command Response Data Format...

Page 29: ...WI for T 0 used to define WWT 8 bClockStop 1 ICC Clock Stop Support 00h Stopping the Clock is not allowed 01h Stop with Clock signal Low 02h Stop with Clock signal High 03h Stop with Clock either High...

Page 30: ...allowed 01h Stop with Clock signal Low 02h Stop with Clock signal High 03h Stop with Clock either High or Low 9 bIFSC 1 Size of negotiated IFSC 10 bNadValue 1 00h Only support NAD 00h Example T0 prot...

Page 31: ...e 10 Summary of Mutual Authentication Commands 6 1 6 1 SPH_to_RDR_ReqAuth This command will request the ACR3901T W1 to perform authentication with the paired key generating device After a successful a...

Page 32: ...ld Size Value Description Encrypted 0 bMessageType 1 20h No 1 LEN1 LEN2 wLength 2 1100h Number of extra bytes starting from the next field for this message and is expressed in two bytes long and LEN1...

Page 33: ...W1 using this command in order to have a successful authentication For more information on the authentication process please refer to Authentication Offset Field Size Value Description Encrypted 0 bM...

Page 34: ...Encrypted 0 bMessageType 1 21h No 1 LEN1 LEN2 wLength 2 1100h Number of extra bytes starting from the next field for this message and is expressed in two bytes long and LEN1 is LSB while LEN2 is MSB...

Page 35: ...um wherein each byte will be encrypted with the Session Key which is generated after mutual authentication using the AES128 CBC cipher mode The initial vector is 16bytes of 00h in AES 128 CBC cipher m...

Page 36: ...ill be encrypted and transmitted after a successful mutual authentication Offset Field Size Value Description Encrypted 0 bMessageType 1 22h No 1 LEN1 LEN2 wLength 2 The number of extra bytes starting...

Page 37: ...nds sent to ACR3901T W1 have to be sent synchronously e g bMaxCCIDBusySlots is equal to 01h for ACR3901T W1 The ACR3901T W1 supported CCID features are indicated in its Class Descriptor Offset Field S...

Page 38: ...ding to parameters Automatic baud rate change according to frequency and FI DI parameters Short and Extended APDU level exchange 44 dwMaxCCIDMessageLength 4 Maximum message length accepted by ACR3901T...

Page 39: ...message and the data returned is the Answer to Reset ATR data 6 2 1 2 PC_to_RDR_IccPowerOff This command deactivates the card slot Offset Field Size Value Description 0 bMessageType 1 63h 1 dwLength 4...

Page 40: ...command APDU begins with this command and continues in the next PC_to_RDR_XfrBlock 0002h the abData field continues a command APDU and ends the APDU command 0003h the abData field continues a command...

Page 41: ...wLength 4 Size of extra bytes of this message 5 bSlot 1 Identifies the slot number for this command 6 bSeq 1 Sequence number for command 7 bProtocolNum 1 Specifies what protocol data structure follows...

Page 42: ...escription 10 bmFindexDindex 1 B7 4 FI Index into the table 7 in ISO IEC 7816 3 1997 selecting a clock rate conversion factor B3 0 DI Index into the table 8 in ISO IEC 7816 3 1997 selecting a baud rat...

Page 43: ...tures Offset Field Size Value Description 0 bMessageType 1 6Bh 1 dwLength 4 Size of abData field of this message 5 bSlot 1 Identifies the slot number for this command 6 bSeq 1 Sequence number for comm...

Page 44: ...1 9 bChainParameter 1 Short APDU level RFU 00h Extended APDU level 00h the response APDU begins and ends in this command 01h the response APDU begins with this command and is to continue 02h this abDa...

Page 45: ...rs and PC_to_RDR_SetParameters messages Offset Field Size Value Description 0 bMessageType 1 82h 1 dwLength 4 Size of extra bytes of this message 5 bSlot 1 Same value as in Bulk OUT message 6 bSeq 1 S...

Page 46: ...ue Description 0 bMessageType 1 83h 1 dwLength 4 Size of extra bytes of this message 5 bSlot 1 Same value as in Bulk OUT message 6 bSeq 1 Same value as in Bulk OUT message 7 bStatus 1 Slot status regi...

Page 47: ...ique serial number of the reader Command Format Offset Field Size Value Description 0 abData1 CommandCode 1 02h Command Code of Get Serial Number 1 Len CommandLength 1 00h Number of extra bytes of dat...

Page 48: ...th mode only Command Format Offset Field Size Value Description 0 abData1 CommandCode 1 03h Command Code of Get Random Number 1 Len CommandLength 1 00h Number of extra bytes of data 2 Data 0 Response...

Page 49: ...of Get Firmware Version 1 Len CommandLength 1 00h Number of extra bytes of data 2 Data 0 Response Format Offset Field Size Value Description 0 abData2 ResponseCode 1 84h Response Code of Get Firmware...

Page 50: ...mmand Code of Rewrite Master Key 1 Len CommandLength 1 20h Number of extra bytes of data 2 Data 32 Combine the random number KeyRstRnd 0 15 encrypted by original Customer Master Key 16 byte of new Cus...

Page 51: ...ld Size Value Description 0 abData1 CommandCode 1 0Dh Command Code of Sleep Mode Option 1 Len CommandLength 1 01h Number of extra bytes of data 2 Data 1 00h 60 seconds Default 01h 90 seconds 02h 120 s...

Page 52: ...ion 0 abData1 CommandCode 1 0Eh Command Code of Get Device Address 1 Len CommandLength 1 00h Number of extra bytes of data 2 Data 0 Response Format Offset Field Size Value Description 0 abData2 Respon...

Page 53: ...mand Code of Set Tx Power 1 Len CommandLength 1 01h Number of extra bytes of data 2 Data 1 00h 18 dBm Default Distance 4 meters 01h 12 dBm Distance 7 meters 02h 6 dBm Distance 16 meters 03h 0 dBm Dist...

Page 54: ...dCode 1 09h Command Code of Read Tx Power 1 Len CommandLength 1 00h Number of extra bytes of data 2 Data 0 Response Format Offset Field Size Value Description 0 abData2 ResponseCode 1 89h Response Cod...

Page 55: ...ize Value Description 0 abData1 CommandCode 1 1Ah Command Code of Set Card Reset Simulation Option 1 Len CommandLength 1 01h Number of extra bytes of data 2 Data 1 00h Disable 01h Enable Response Form...

Page 56: ...Size Value Description 0 abData1 CommandCode 1 1Ah Command Code of Get Card Reset Simulation Option 1 Len CommandLength 1 00h Number of extra bytes of data 2 Data 0 Response Format Offset Field Size V...

Page 57: ...1 CommandCode 1 18h Command Code of Set Card Response Time Interval 1 Len CommandLength 1 01h Number of extra bytes of data 2 Data 1 00h 0s 01h 500 ms 02h 1000 ms 03h 1500 ms Default 04h 2000 ms 05h 2...

Page 58: ...ion 0 abData1 CommandCode 1 19h Command Code of Get Card Response Time Interval 1 Len CommandLength 1 00h Number of extra bytes of data 2 Data 0 Response Format Offset Field Size Value Description 0 a...

Page 59: ...cription 0 abData1 CommandCode 1 1Bh Command Code of Check button status 1 Len CommandLength 1 00h Number of extra bytes of data 2 Data 0 Response Format Offset Field Size Value Description 0 abData2...

Page 60: ...1 Generate random number Customer Master Key Reset Request 0F 00 Customer Master Key Reset Command Response 8F 10 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 2 Encrypt the random number and new cu...

Page 61: ...ommand Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS P1 P2 Lc Card Type FFh A4h 00h 00h 01h 01h Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Where SW1 SW2 9...

Page 62: ...address location of the memory card MEM_L Length of data to be read from the memory card Response Data Format abData field in the RDR_to_PC_DataBlock BYTE 1 BYTE N SW1 SW2 Where BYTE x Data read from...

Page 63: ...ACR3901T W1 Reference Manual info acs com hk Version 1 02 www acs com hk Page 63 of 100 Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Where SW1 SW2 90 00h if no error...

Page 64: ...field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS P1 P2 Lc Card Type FFh A4h 00h 00h 01h 02h Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Where SW1 SW2 90 00h if no error 7...

Page 65: ...kilobit iic card where is the MSB of the 17 bit addressing Byte Address Memory address location of the memory card MEM_L Length of data to be read from the memory card Response Data Format abData fie...

Page 66: ...Page 66 of 100 Byte Address Memory address location of the memory card MEM_L Length of data to be written to the memory card Byte x Data to be written to the memory card Response Data Format abData f...

Page 67: ...ormat abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS P1 P2 Lc Card Type FFh A4h 00h 00h 01h 03h Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Where SW1 SW2 90 00h if...

Page 68: ...ddress location of the memory card MEM_L Length of data to be written to the memory card MEM_D Data to be written to the memory card Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW...

Page 69: ...7 2 3 5 INITIALIZE_AUTHENTICATION Command Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS P1 P2 Lc Q 0 Q 1 Q 7 FFh 84h 00h 00h 08h Where Q 0 Q 1 Q 7 Host random number 8 bytes Respon...

Page 70: ...DU CLA INS P1 P2 Lc Card Type FFh A4h 00h 00h 01h 04h Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Where SW1 SW2 90 00h if no error 7 2 4 2 READ_MEMORY_CARD Command Format abDa...

Page 71: ...e memory address location of the memory card 1000 0000b for writing fuse MEM_L Length of data to be written to the memory card Byte x Data to be written to the memory card Response Data Format abData...

Page 72: ...5 INITIALIZE_AUTHENTICATION Command Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS P1 P2 Lc Q 0 Q 1 Q 7 FFh 84h 00h 00h 08h Where Byte Address Memory address location of the memory...

Page 73: ...ACR3901T W1 Reference Manual info acs com hk Version 1 02 www acs com hk Page 73 of 100 Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Where SW1 SW2 90 00h if no error...

Page 74: ...ld in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS P1 P2 Lc Card Type FFh A4h 00h 00h 01h 05h Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Where SW1 SW2 90 00h if no error 7 2 5...

Page 75: ...d is locked exceeded the maximum number of retries Other values indicate that the last verification has failed DUMMY Two bytes dummy data read from the card SW1 SW2 90 00h if no error 7 2 5 4 READ_PRO...

Page 76: ...TE x in the response data 0 byte is write protected 1 byte can be written 7 2 5 5 WRITE_MEMORY_CARD Command Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS Byte Address MEM_L Byte 1...

Page 77: ...g at Byte Address BYTE 1 is compared with the data at Byte Address BYTE N is compared with the data at Byte Address N 1 Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Where SW1 S...

Page 78: ...Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 ErrorCnt 90h Where SW1 90h SW2 ErrorCnt Error Counter FFh indicates successful verification 00h indicates that the password is locked or ex...

Page 79: ...C specifications Command Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS P1 P2 Lc Card Type FFh A4h 00h 00h 01h 06h Response Data Format abData field in the RDR_to_PC_DataBlock SW1 S...

Page 80: ...r 07h indicates that the last verification is correct 00h indicates that the password is locked exceeded the maximum number of retries Other values indicate that the last verification has failed DUMMY...

Page 81: ...location of the memory card MEM_L Length of data to be written to the memory card Byte x Data to be written to the memory card Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Whe...

Page 82: ...2 card the following actions are executed 1 Search a 1 bit in the presentation error counter and write the bit to 0 2 Present the specified code to the card 3 Try to erase the presentation error count...

Page 83: ...d The current secret code must have been presented to the card with the PRESENT_CODE command prior to the execution of this command Command Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CL...

Page 84: ...specifications Command Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS P1 P2 Lc Card Type FFh A4h 00h 00h 01h 07h Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2...

Page 85: ...to the card Backup bit is enabled to prevent data loss when card tearing occurs d Write with carry and backup enabled SLE 4436 SLE 5536 and SLE 6636 only The byte value specified in the command is wri...

Page 86: ...RDR_XfrBlock Pseudo APDU CLA INS P1 P2 MEM_L CODE ADDR Byte 1 Byte 2 Byte 3 FFh 20h 00h 00h 04h 09h Where ADDR Byte address of the presentation counter in the card CODE Three bytes secret code PIN Res...

Page 87: ...g 80h Key 1 with cipher block chaining SLE 5536 and SLE 6636 only 81h Key 2 with cipher block chaining SLE 5536 and SLE 6636 only CLK_CNT Number of CLK pulses to be supplied to the card for the comput...

Page 88: ...ACR3901T W1 Reference Manual info acs com hk Version 1 02 www acs com hk Page 88 of 100 the first authentication bit read from the card SW1 SW2 90 00h if no error...

Page 89: ...SC specifications Command Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS P1 P2 Lc Card Type FFh A4h 00h 00h 01 08h Response Data Format abData field in the RDR_to_PC_DataBlock SW1...

Page 90: ...yte Address Memory address location of the memory card MEM_L Length of data to be written to the memory card BYTE Byte value to be written to the card Response Data Format abData field in the RDR_to_P...

Page 91: ...r counter The User Error Counter can be erased when the submitted code is correct Command Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS Error Counter LEN Byte Address MEM_L CODE By...

Page 92: ...t to 0 3 Erase the presentation error counter Please note that Memory Error Counter cannot be erased Command Format abData field in the PC_to_RDR_XfrBlock Response Data Format abData field in the RDR_...

Page 93: ...refer to PC SC specifications Command Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS P1 P2 Lc Card Type FFh A4h 00h 00h 01h 09h Response Data Format abData field in the RDR_to_PC_Da...

Page 94: ...e Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Where SW1 SW2 90 00h if no error 7 2 9 4 ERASE_NON_APPLICATION_ZONE This command is used to erase the data in Non Application Zones The EE...

Page 95: ...6 AT88SC1003 To erase the data in Application Zone 3 The following actions are executed for this command 1 Present the specified code to the card a Erase the presentation error counter The data in cor...

Page 96: ...d in the following cases 1 AT88SC101 To erase the data in Application Zone with EC Function Enabled 2 AT88SC102 To erase the data in Application Zone 2 with EC2 Function Enabled 3 AT88SC1003 To erase...

Page 97: ...FY_SECURITY_CODE This command is used to submit Security Code 2 bytes to the inserted card Security Code is to enable the memory access of the card The following actions are executed 1 Present the spe...

Page 98: ...mmand Format abData field in the PC_to_RDR_XfrBlock Pseudo APDU CLA INS Error Counter LEN Byte Address MEM_L CODE Fuse Bit Addr High Fuse Bit Addr Low State of FUS Pin State of RST Pin FFh 05h 00h 00h...

Page 99: ...ACR3901T W1 Reference Manual info acs com hk Version 1 02 www acs com hk Page 99 of 100 Response Data Format abData field in the RDR_to_PC_DataBlock SW1 SW2 Where SW1 SW2 90 00h if no error...

Page 100: ...9h Exceeded max authentication retry failure 0Ah T1 Card operation error Table 11 Error Code Android is a trademark of Google Inc Atmel is a registered trademark of Atmel Corporation or its subsidiari...

Reviews: