ENGLISH / A-11
FORM NO. - 56041706 - 34 RST -
A-11
FILLING THE SOLUTION TANK
Fill the solution tank with a maximum of 30 gallons (113.5 Liters) of cleaning solution. Do not
fi
ll the solution tank above 7.5 cm (3 inches) from the
bottom of the Solution Fill
(1)
. The solution should be a mixture of water and the proper cleaning chemical for the job. Always follow the dilution
instructions on the chemical container label.
CAUTION!
Use only low-foaming, non-
fl
ammable liquid detergents intended for machine application. Water temperature should not exceed 130
degrees fahrenheit (54.4 degrees celsius)
SQUEEGEE INSTALLATION
1
See Figure 3.
Slide the Squeegee Assembly
(13)
onto the squeegee mount bracket and tighten the Squeegee Mount Thumb Nuts
(25)
.
2
Connect the Recovery Hose
(19)
to the squeegee inlet.
3
Lower the squeegee, move the machine ahead slightly and adjust the squeegee tilt using the Squeegee Adjustment Knob
(26)
so that the
rear squeegee blade touches the
fl
oor evenly across its entire width and is bent over slightly as shown.
FIGURE 3
Summary of Contents for 34 RST
Page 14: ...ENGLISH A 13 FORM NO 56041706 34 RST A 13 WET SCRUBBING 28 30 17 27 19 2 13 A B F G E 5 29 29...
Page 21: ......
Page 39: ......
Page 40: ......