SES Values in E1A or E1B Performance History Menu
This value indicates the number of Severely Errored Seconds in the E1 data stream.
Possible Cause
•
When CRC is enabled, a severely errored second is listed when more than 805 CRCs occur
within that second.
•
When CRC is disabled
,
an errored second is listed when more than 850 CVs occur within
that second.
Recommended Actions:
1.
Check the E1 signal with a BERT test set to determine origin of error.