TRACER 2 x E1 User’s Manual
61280004L2-1C
Section 2 Installation
13
E1 Interfaces
The E1 interface conforms to the ITU G.703 and G.704 electrical and signaling interfaces
recommendations. Two interfacing configurations are available:
• 75
Ω
unbalanced BNC coaxial connectors.
• 120
Ω
balanced 15 pin / RJ48 connectors with the pinouts shown here.
15 Pin
RJ-48
Pin
Function
Pin
Function
1
E1 Out ring
1
E1 Out ring
2
Frame ground
2
E1 Out tip
3
E1 In ring
3
N.C.
4
Frame ground
4
E1 In ring
5
N.C.
5
E1 In tip
6
N.C.
6
N.C.
7
N.C.
7
N.C.
8
N.C.
8
N.C.
9
E1 Out tip
10
N.C.
11
E1 In tip
12
N.C.
13
N.C.
14
N.C.
15
N.C.
The 75
Ω
unbalanced interface provides two pair of 75
Ω
BNC connectors. The shield of the OUT
coaxial connection is attached to earth ground. A jumper is provided to optionally connect the shield of
the INPUT coaxial connection to ground as described in G.703. This jumper is located on the inside of
the E1 interface board, between each of the two BNC connectors. The E1 module must be removed to
access this option.
The 120
Ω
balanced interface provides two individual 120
Ω
15-pin connectors.
Summary of Contents for TRACER 2xE1
Page 1: ...TRACER 2 x E1 User s Manual 2001 61280004L2 1C TRACER 2 x E1 User s Manual...
Page 2: ...TRACER 2 x E1 User s Manual 2001 61280004L2 1C...
Page 10: ...TRACER 2 x E1 User s Manual 61280004L2 1C Table of Contents viii...
Page 34: ...TRACER 2 x E1 User s Manual 61280004L2 1C Section 2 Installation 24...
Page 54: ...TRACER 2 x E1 User s Manual 61280004L2 1C Section 4 Troubleshooting 44...
Page 60: ...TRACER 2 x E1 User s Manual 61280004L2 1C Glossary 50...
Page 62: ...TRACER 2 x E1 User s Manual 61280004L2 1C Appendix A Cable Connections A 2...