TRACER 2 x E1 User’s Manual
61280004L2-1C
Section 1 TRACER Description
4
A block diagram of the BBP is shown in
Figure 1-5
.
VT100 RS-232 Interface
An RS-232 interface is provided via a 25-pin D connector for attaching a VT100 compatible terminal.
The active signals used on this interface are listed below
Signal Name
Pin Number
Source
Transmit Data .......... 2 ............. Terminal/Modem
Receive Data ............ 3 ............. TRACER
Request to Send ....... 4 ............. Terminal/Modem
Clear to Send ............ 5 ............. TRACER
Data Set Ready ........ 6 ............. TRACER
Signal Ground .......... 7
The management system allows the E1 interfaces to be provisioned. The line code can be selected as
AMI or HDB3. The signaling can be selected as channel associated signaling (CAS) or common channel
signaling (CCS). Alarm conditions can also be monitored. The management system will report the
following alarms on the E1 interfaces:
Figure 1-5. BBP Block Diagram
Σ
E1
Data
Multiplexer
Viterbi
Encoder/
Decoder
Spread
Spectrum
Data
Pump
90
90
Baseband Processor Board
IF Interface Board
Fc = 70 MHz
Fc = 140 MHz
Filter
µ
C
UART
DSP
21-56
VDC
RS-232
E1 A
IF
E1
E1 B
Summary of Contents for TRACER 2xE1
Page 1: ...TRACER 2 x E1 User s Manual 2001 61280004L2 1C TRACER 2 x E1 User s Manual...
Page 2: ...TRACER 2 x E1 User s Manual 2001 61280004L2 1C...
Page 10: ...TRACER 2 x E1 User s Manual 61280004L2 1C Table of Contents viii...
Page 34: ...TRACER 2 x E1 User s Manual 61280004L2 1C Section 2 Installation 24...
Page 54: ...TRACER 2 x E1 User s Manual 61280004L2 1C Section 4 Troubleshooting 44...
Page 60: ...TRACER 2 x E1 User s Manual 61280004L2 1C Glossary 50...
Page 62: ...TRACER 2 x E1 User s Manual 61280004L2 1C Appendix A Cable Connections A 2...