20
Section 61181300L1-5C, Issue 3
61181300L1-5C
Shelf: Slot: Total Access System
02:24:18 02/18/98
Unacknowledged Alarm: None
ES Threshold (15 Min.):
30
1. 30
2. 150
Selection:
? - System Help Screen
Figure 22. ES Threshold (15-Minute) Screen
Changing Alarm Settings and Thresholds
1. From the QFO-C Main Menu screen, type “4” and
press Enter to select Alarms. The Alarms Screen
(Figure 19) will appear.
2. Type “2” and press Enter to select Alarm
Provisioning. The Alarm Provisioning Screen
(
Figure 21
) will appear.
Setting the ES Threshold (15-Min.)
1. From the Alarm Provisioning Screen, type “1” and
press Enter to select ES Threshold (15-Min.). The ES
Threshold Screen (
Figure 22
) will appear. Type the
number of desired setting and press Enter.
Figure 21. Alarm Provisioning Screen
Shelf: Slot:
Total Access System
02/18/98 02:24:18
Unacknowledged Alarms: None
Alarm Provisioning
1. ES Threshold (15 Min.)
30
2. SES Threshold (15 Min.)
15
3. UAS Threshold (15 Min.)
15
4. ES Threshold (24 Hours)
14400
5. SES Threshold (24 Hours)
7200
6. UAS Threshold (24 Hours)
7200
Selection:
‘?’ - System Help Screen