Unit Installation
NetVanta 1224STR DC Hardware Installation Guide
40
Copyright © 2013 ADTRAN, Inc.
61200590E1-34B
Figure 17. Installing DIMs
Instructions for Installing the DIMs
Step
Action
1
Remove power from the unit.
2
If the NIM is already in the NetVanta chassis, remove all cables, release the pins at both edges
of the NIM front panel, and slide the module out of the chassis.
3
Carefully align the P1 connector on the NIM with the J1 connector on the DIM.
Using only
fingertip
pressure
so that neither circuit board bends or flexes, ensure that the connectors are firmly seated.
Secure the DIM to the NIM using the screws and standoff posts supplied. See
.
4
Slide the NIM with the DIM attached into the NetVanta chassis, continuing with the normal NIM
installation (refer to
Instructions for Installing the NIMs on page 41
).