Warranty:
ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can be
found online at
www.adtran.com/warranty
.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61172838G1-22B*
S
PECIFICATIONS
Specifications
for
the
NetVanta
838T
are
as
follows:
♦
Electrical
◊
Voltage
Rating:
100–240
VAC,
50/60
Hz
◊
Current
Rating:
1
Amp
◊
Typical
Operating
Power:
•
13
watts,
0.25
amps
@
120
VAC
•
14
watts,
0.15
amps
@
240
VAC
♦
Environmental
◊
Operational
Temperature
Range:
–40°C
to
+65°C
◊
Storage
Temperature
Range:
–40°C
to
+85°C
◊
Relative
Humidity:
up
to
95%,
noncondensing
♦
Physical
◊
Height:
1.75
inches
◊
Width:
12
inches
◊
Depth:
8
inches
◊
Weight:
4
pounds
♦
Connectors
◊
SHDSL
Port:
RJ
‐
48C
◊
10/100Base
‐
T
Ethernet:
RJ
‐
45
◊
Craft
Port:
DB
‐
9
female
♦
Diagnostics
and
Test
◊
Self
‐
diagnosis
C
OMPLIANCE
CAUTION
!
Electrostatic
Discharge
(ESD)
can
damage
electronic
modules.
When
handling
modules,
wear
an
antistatic
discharge
wrist
strap
to
prevent
damage
to
electronic
components.
Place
modules
in
antistatic
packing
material
when
transporting
or
storing.
When
working
on
modules,
always
place
them
on
an
approved
antistatic
mat
that
is
electrically
grounded.
The
NetVanta
838T
(P/N
1172838G1)
has
been
evaluated
to
inter
‐
national
safety
standards
EN
60950
‐
1,
AS/NZS
60950.1,
and
IEC
60950
‐
1.
The
NetVanta
838T
meets
the
requirements
for
CE
marking
under
the
EMC
Directive
and
Low
Voltage
Directive.
Standards
used
to
demonstrate
Compliance
are
EN
300
386
and
EN
60950.
This
device
complies
with
ETSI
EN
300
386
“Electromagnetic
compatibility
and
Radio
spectrum
Matters
(ERM);
Telecommuni
‐
cation
network
equipment;
Electromagnetic
Compatibility
(EMC)
requirements.”
Changes
or
modifications
not
expressly
approved
by
ADTRAN
could
void
the
user’s
authority
to
operate
this
equipment.
NOTE
♦
The
SHDSL
ports
are
suitable
for
connection
to
external
or
exposed
wiring
or
cabling.
The
ports
meet
the
lightning
and
power
fault
criteria
with
any
primary
protector
that
meets
any
of
the
voltage
limits
of
ITU
‐
T
Recommendations
K.12,
K.28
or
IEC
61543
‐
1
(that
is,
GDT,
SSA
or
MOV).
♦
The
10/100Base
‐
T
Ethernet
ports
are
suitable
for
connection
to
internal
or
unexposed
wiring
or
cabling
only.
Do
not
metallically
connect
these
ports
to
interfaces
that
connect
to
external
wiring.
The
Ethernet
ports
are
designed
for
use
as
internal
interfaces
only
and
require
isolation
from
exposed
external
cabling.
The
addition
of
Primary
Protectors
is
not
sufficient
protection
in
order
to
connect
these
interfaces
metallically
to
external
or
exposed
wiring.
♦
Current
limiting
protectors
are
not
required
and
may
adversely
affect
performance
if
utilized.
The
NetVanta
838T
is
designed
to
meet
the
following
environ
‐
mental
classes:
♦
ETSI
EN
300
019
‐
1
‐
1
“Classification
of
environmental
conditions,
Storage”
‐
Class
1.2
♦
ETSI
EN
300
019
‐
1
‐
2
“Classification
of
environmental
conditions,
Transportation”
‐
Class
2.3
♦
ETSI
EN
300
019
‐
1
‐
3
“Classification
of
environmental
conditions,
Stationary
use
at
weather
‐
protected
locations”
‐
Class
3.3
The
equipment
is
designed
to
function
without
degradation
during
exposure
to
all
test
severities
per
Class
3.3
in
ETSI
EN
019
‐
1
‐
3.
www.adtran.com
for
further
information
on
RoHS/WEEE.
C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.