Chapter 3. Operation
61200.184L1-1
Quad Nx 56/64 Module User Manual
11
NO EXT CLK
The DTE is not providing an external transmit clock (only if the V.35 Nx
port is configured to get transmit clock from the DTE.)
DTE Status
Read security: 5
Shows the status of key DTE interface signals. The following signals are
monitored (these options are read-only):
RTS
Request To Send from DTE
CTS
Clear To Send to DTE
DTR
Data Terminal Ready from DTE
DSR
Data Set Ready to DTE
DCD
Data Carrier Detect to DTE
RI
Ring Indicate to DTE
TD
Transmit Data from the DTE
RD
Receive Data toward the DTE
Data Rate
Read security: 5
Displays the data rate at which each Nx port is currently operating. A
port’s data rate is determined by the number of DS0s assigned to it and the
rate per DS0 associated with the active maps.
Inband
Read security: 5
ID
Correct Unit ID
PASS
Correct Password
CRC
Correct CRC