Chapter 3. Operation
61200.184L1-1
Quad Nx 56/64 Module User Manual
9
Menu
Selecting this item displays additional status and configuration menus
about the selected module. (To access the submenus for this item, use the
arrow keys to scroll to the Menu column for the module you want to edit,
and press
Enter
.) For detailed information on each submenu item, see the
Quad Nx 56/64 Module Menu Options
Alarms
Read security: 5
This field displays whether there is an alarm condition on the Quad Nx
56/64 Module. Press
Enter
in this field to activate the Alarm menu.
Test
Read security: 5
This field displays whether the Quad Nx 56/64 Module is executing a
test. Press
Enter
in this field to activate the Test menu.
State
Write security: 3; Read security: 5
Even though a module is physically installed, it must be marked Online
for it to be considered an available resource. This parameter allows an
installed module to be marked Offline, which may be useful in system
troubleshooting.
Status
Read security: 5
This is a read-only field presenting status information on the Quad Nx
56/64 Module. The following messages may display:
Hardware Revision
Read security: 5
This is a read-only field that displays the hardware revision of the Quad
Nx 56/64 Module.
Online:
The module is enabled, and is responding to the Sys-
tem Controller’s status polls. This is the normal
response of the system.
No Response:
The module is enabled, but is not responding to the
System Controller’s status polls. This response indi-
cates either a problem in the system or that the mod-
ule is not installed.
Empty:
The System Controller has not detected the presence
of a module in the slot, nor has a module been manu-
ally enabled for this option slot.
Offline
The module is installed, but has been taken Offline
by a user. The module is still responding to controller
polls.
Offline/
No Response:
The module is installed, but has been taken Offline
by a user. The module is not responding to polls.