Total Access 3000 23-Inch Chassis Installation and Maintenance Practice
2
61181001L1-5E
The Total Access 3000 Chassis terminates up to 112 DSX-1/E1s and/or a single high speed
(DS3, STS-1, etc.) signal from the network and provides the necessary circuits to interface
with up to 224 2-wire loops to the customer’s equipment.
The Total Access 3000 Chassis mounts in a standard 23-inch wide rack. The chassis
measures 21.40 inches wide, 6 inches high, and 12 inches deep, and weighs 13.45 pounds.
The operating temperature range for the chassis is –40°C to 65°C for remote terminal
applications.
Compliance
shows the Compliance Codes for the Total Access 3000 Chassis. The Total Access
3000 Chassis is NRTL listed to the applicable UL standards. The Total Access 3000 Chassis is
to be installed in a restricted access location and in a Type “B” or “E” enclosure only.
CAUTION
Per GR-1089-CORE October 2002, Section 9, the Total Access 3000
Chassis is designed and intended only for installation in a DC-C
(common) bonding and grounding system. The chassis ground wire
must be of equal or greater ampacity than the wire connected to
the –48 VDC return.
The Total Access 3000 Chassis is not intended or designed for
installation in a DC-I (isolated) bonding and grounding system.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority
to operate this equipment.
NOTE
Champ connectors should only be connected to intra-building
wiring and circuits.
Table 1. Compliance Codes
Code
Input
Output
Power Code (PC)
F
C
Telecommunication Code (TC)
X
X
Installation Code (IC)
B
–