Q2BYG808MD
Driver
User’s
Manual
-20-
(1)
Four
‐
wire
motor:
Only
one
connection
is
available;
DIP
switch
setting
current
should
be
≤
rated
motor
current.
(2)
Six
‐
wire
motor:
Two
connection
methods
are
available,
as
follows:
Connection
method
Applications
Terminals
Features
Serial
connection
Speed
≤
200rpm,
occasions
require
high
torque
A+,
A
‐
B+,
B
‐
Motor
torque
is
high
at
low
speed
and
low
at
high
speed.
It
is
easy
to
heat
when
the
motor
is
running.
DIP
switch
settings
current
≤
50%
rated
current.
Center
point
connection
200rpm
≤
speed
≤
600rpm,
occasions
require
high torque
A+,
A
‐
B+,
B
‐
Motor
torque
is
low
at
low
speed
and
high
at
high
speed.
DIP
switch
setting
current
≤
rated
current.
(3)
Eight
‐
wire
motor:
Two
connection
methods
are
available,
as
follows:
Connection
method
Applications
Terminals
Features
Serial
connection
Speed
≤
200rpm,
occasions
require
high
torque
Two
wires
of
center
tap
are
short
connected,
and
the
connected
drive
terminals
are
A
+,
A
‐
,
B
+,
B
‐
Motor
torque
is
high
at
low
speed
and
low
at
high
speed,
and
heating
is
serious.
DIP
switch
settings
current
≤
50%
rated
current.
Parallel
connection
200rpm
≤
speed
≤
600rpm,
occasions
require
high
torque
Two
wires
of
center
tap
are
connected
to
the
two
wires
in
parallel,
and
the
connected
drive
terminals
are
A
+,
A
‐
,
B
+,
B
‐
,
Motor
torque
is
low
at
low
speed
and
high
at
high
speed.
DIP
switch
setting
current
≤
1.4*rated
current.