Q2BYG808MD
Driver
User’s
Manual
-34-
No.
Parameter
name
Function
Range
14
‐
100 Pulses
per
revolution:
20000
15
‐
150
Pulses
per
revolution:
30000
16
‐
200
Pulses
per
revolution:
40000
P5
Pulse
mode
Input
instruction
pulse
mode.
0
‐
PU+DR(100K),
single
pulse
1
‐
CW+CCW,
double
pulse
2
‐
A+B
quadrature
pulse
3
‐
PU+DR(500K)
single
pulse
0
‐
3
P6
Working
mode
The
drive
controls
motor
mode:
0
‐
external
pulse
subdivision,
control
command
impulse
through
external
port,
number
of
subdivisions
is
active,
1
‐
electronic
gear;
control
command
impulse
through
external
port,
number
of
subdivisions
is
inactive;
determine
the
number
of
pulses
per
revolution
according
to
electronic
gear
numerator
and
denominator
2
‐
internal
position,
the
rising
edge
of
PU
signal
triggers
internal
position
to
start,
run
corresponding
distance
according
to
the
P17,
P18,
P19,
P20.
Direction
DR
is
inactive.
3
‐
start
internal
speed
after
power
‐
on,
drive
is
powered,
and
motor
runs
continuously
at
the
speed
set
by
P23
and
the
direction
set
by
P16.
External
signal
is
inactive,
and
the
number
of
subdivisions
is
inactive.
4
‐
level
controls
internal
speed,
the
drive
is
powered,
DR
is
low
level,
and
the
motor
stops;
DR
is
high
level,
the
motor
starts
and
runs
continuously
at
the
speed
set
by
P23
and
the
direction
set
by
P16.
External
signal
is
inactive,
and
the
number
of
subdivisions
is
inactive.
5
‐
custom
according
to
special
requirements
0
‐
5