
XT20100820 HC8200 Flame Cutting Machine User’s Manual
3-45
You can press Space to change output level status. Refer to hardware input/output port (Definition of output ports)
for the signs and definitions of each output port.
2) Input detection: display the status of the current optical isolation input. Green “
” means input signal
is detected at the current position, and red “ ” means this port has no setting. For example: if input signal is
detected at “Port 00”, then the red lights after it will become green. Refer to hardware input/output port
(Definition of output ports) for the signs and definitions of each import port.
3) Keyboard detection: press any key in the keyboard at the corresponding position and the pressed key
will be displayed on the screen. If no response on the screen even after a key is pressed for many times, or the
position is not correct, it means the system is not functioning well.
3.2.4.7
F7
Consumable
。
This interface is used to track and record the useful life of the spare parts. If you press the new nozzle or
new electrode key every time after replacing the nozzle or electrode, then the information of the previous nozzle
or electrode will be updated. This function allows you to view the time of replacement of the wearing parts and
calculate the useful life based on minute or perforation times. The wearing parts replacement prompt may be
adopted and in such case, when a wearing part reaches the use time limit, the system will prompt.
Figure 3.2.4.6.4 Replace spare parts
Summary of Contents for ADT-HC8200
Page 5: ......
Page 11: ......
Page 22: ...Chapter 2 2 12 Figure 2 4 1 1 2 Side view of AIO controller...
Page 25: ......
Page 93: ......