special IFB receiver or manual PID
selection with a standard IRD.
Note: There is no PID reference in
the PMT for this functionality. It is
considered a ghost PID. It is also
not lip-sync aligned with video.
5.12
SDI Pair
Allows the operator to route
embedded audio from SDI input to
the specified audio encoder.
1-8
5.13
SDI Clock
Source
The embedded audio clock source
configuration determines whether
to use the embedded clock phase
words or derive from video clock.
Default is EMBEDDED. If the SDI
source has problem (or
non-compliant) embedded audio
clock phase words, then choose
the video clock as the source. Note
that choosing the video clock
requires that all audio channels are
embedded in a fully synchronous
fashion.
EMBEDDED
VIDEO
5.14
ECC Words
Default is ON. Select OFF if the SDI
source has problematic (or
non-compliant) ECC words.
OFF
ON
5.15
Audio Level
B-DL
Mapping
The 3G-SDI Level B Source
configuration is only valid with
3G-SDI Level B sources. 16
channels of audio can be extracted
from either LINKA, the default
configuration, or LINKB.
LINKA
LINKB
6. PIDs Menu
Item
Function
Options
6.1
Transport
Stream ID
Sets the Transport Stream ID in PAT and other
tables in the egress transport stream.
Configure this value in Hex.
0x0001 - 0x1FFE
6.2
PMT PID
PMT PID refers to the PID of the Program Map
Table (PMT). Program Map Tables are used to
describe the properties of a single program.
user-defined using