– 9 –
5800 Series Transmitter Input Loop Identification
• All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes.
Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming
zones).
• Transmitter inputs entered as:
"RF" (Supervised RF) Type send periodic check-in signals, as well as fault, restore and low battery
signals. The transmitter must remain within the receiver's range.
“UR" (Unsupervised RF) Type send all the signals that the "RF" Type does, but the control does
not supervise the check-in signals. The transmitter may, therefore, be carried off-premises.
"BR" (Unsupervised Button RF) Type only send fault signals. Restore or check-in signals are not
sent, but low battery signals are sent when a button is pressed. The transmitter may be carried off -
premises.
3
4
1
2
(ALWAYS USE)
INPUT
(LOOP)
5 8 0 1
LEARN AS "UR" OR "RF"
INPUT
(LOOP)
1
5 8 0 2 M N
LEARN AS "UR" OR "RF"
YOU MUST
LEARN THIS
BUTTON
LOOP 3
LOOP 1
LOOP 2
LOOP 4
INPUT
(LOOP)
1
5808
LEARN AS "RF"
5 8 0 4
LEARN
AS "BR"
5 8 1 7
LEARN AS "RF"
INPUT
(LOOP)
1
(PRIMARY)
2
(AUX. CENTER)
3
(AUX. RIGHT)
INPUT
(LOOP)
1
(MOTION)
5 8 9 0
LEARN AS "RF"
5 8 1 6
LEARN AS "RF"
INPUT
(LOOP)
2
(REED)
LOOP 1
(TERMINALS)
5 8 2 7
SET HOUSE CODE
5 8 2 7 B D
SET HOUSE CODE
5 8 1 6 M N
LEARN AS "RF"
INPUT
(LOOP)
2
(REED)
LOOP 1
(TERMINALS)
5 8 1 9
LEARN AS "RF"
INPUT
(LOOP)
2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP2
LOOP 3
(TERMINALS)
5 8 1 9 S ( W H S & B R S )
LEARN AS "RF"
INPUT
(LOOP)
2
(REED)
LOOP 1
(INTERNAL
SHOCK
SENSOR)
LOOP 3
(TERMINALS)
5 8 5 0 ( G B D )
LEARN AS "RF"
(Green)
(Red)
(Yellow)