– 18 –
✱
72
BYPASS RESTORE REPORT CODE
(2-Digit Entry)
(See box on previous page) . This is sent when a zone that has been
bypassed is un-bypassed.
✱
73
AC RESTORE REPORT CODE
(2-Digit Entry)
(See box on previous page) . Reports with Subscriber No.
✱
74
LOW BAT RESTORE REPORT CODE
(2-Digit Entry)
(See box on previous page). Reports with Subscriber No.
✱
75
RF XMTR. LOW BATTERY RESTORE CODE
(2-Digit Entry)
(See box on previous page). This is sent when a transmitter that
previously sent in a low battery message has sent a message
indicating it no longer has a low battery condition.
OUTPUT AND SYSTEM
SETUP (
✱
80 –
✱
92)
✱
80
OUTPUT RELAYS
This is a menu mode that is applicable only if 4204 relays are to be
used (“3” in field
✱
25). See the RELAY OUTPUTS section in the
Installation Instructions for a detailed programming procedure. Also
refer to the OUTPUT RELAY table for field
✱
80 in the Programming
Form in this manual.
✱
81
ZONE LISTS FOR OUTPUT DEVICES
This is a menu mode that is applicable only if field
✱
25 is
programmed for a 4204 relay. Refer to the RELAY OUTPUTS section
in the Installation Instructions for a detailed programming
procedure. Also refer to the ZONE LISTS FOR OUTPUT RELAYS
table for
✱
81 in the Programming Form in this manual.
✱
82
CUSTOM ALPHA EDITING
S e e the ALPHA DESCRIPTION PROGRAMMING section in the
Installation Instructions for procedure.
✱
83
SEQUENTIAL MODE
Used for “enrolling” transmitters in a 5800 RF system after all other
zone information has been programmed.
✱
90
PAGER CHARACTERS
(Up to 16 digits)
Optional 16 digits for Account numbers, PIN numbers, or any
additional data that you wish to precede the 7-digit status code sent to
a pager. See field
✱
47 SPLIT/DUAL REPORTING.
Enter 0–9; # + 11 for '
✱
'
; # + 12 for '#'; # + 13 for a pause (2 secs).
✱
91
OPTION SELECTION
(1-Digit Entry)
Enter “4” or “#” + “12” if an Audio Alarm Verification (AAV) unit is
connected in the system (1–3 not used); enter “0” for UL installations,
or if no AAV unit is being used.
Other selections available in this field are:
“8” for Exit Delay restart (this allows use of [
✱
]
key to restart exit
delay when armed STAY). This is the default.
“#” + “12” for AAV plus Exit Delay restart.
Important : AAV should not be used when Paging or Alarm Reports
are being sent to a Secondary number. If this is done, the call to the
Secondary number by the communicator after the alarm report will
prevent the AAV from taking control of the telephone line, and the
AAV “Listen in” session cannot take place.
✱
92
NUMBER OF REPORTS IN ARMED PERIOD
(1-Digit Entry)
This option can be used to limit the number of messages (alarm & alarm
restore reports) sent to the central station in an armed period. “0” limits
reports to a total of 10; “1” allows an unlimited number of reports.
UL
“1” must be selected for UL installations
Summary of Contents for SA10ADTEG
Page 22: ... 22 NOTES ...