Night Arming

To fully arm the system when it has been armed in Stay Mode, press 

 at the keypad. All inte-

rior zones will now be armed except for devices programmed as Night Zones. 
Night zones are only armed in Away mode, this permits limited movement within the premises when
the system is fully armed. Ensure that your installer has provided you with a list identifying zones pro-
grammed as night zones.
When the interior zones have been activated (i.e., 

) you must enter your access code to dis-

arm the system to gain access to interior areas that have not been programmed as night zones.

Silent Exit Delay

If the system is armed using the Stay key or using the ’No Entry’ Arming method (

[access

code]), the audible progress annunciation (keypad buzzer) will be silenced and the exit time will be
doubled for that exit period only.

Away Arming

Close all sensors (i.e. stop motion and close doors). The Ready (

) indicator should be on.

To arm, press and hold the Away Key for 2 seconds and/or enter your Access Code, or press 
to Quick Arm. During the setting state (exit delay active) the Armed ( ) and Ready (

) indicators will

turn on, and the keypad will sound one beep per second. You now have ____ seconds to leave the
premises (please check with your installer to have this time programmed). An audible annunciation,
whose pulsating rate is distinctly different, will sound during the last ten seconds of the exit delay to
warn person(s) that the exit delay is running out. To cancel the arming sequence, enter your access
code.
When the exit delay is completed, the alarm system is armed/set and this is indicated on the keypad
as follows: the Ready (

) indicator will turn off, the Armed ( ) indicator will remain on and the key-

pad will stop sounding. 

NOTE: If your system is installed in accordance with SIA CP-01 Standard for False Alarm 
Reduction then the violation, restoral followed by a second violation of the entry/exit zone before 
the end of the exit delay will restart the exit delay.

Quick Exit

If the system is armed and you need to exit, use the Quick Exit function to avoid disarming and
rearming the system. Press and hold the Quick Exit key for 2 seconds or press 

. You now have

2 minutes to leave the premises through your exit door. When the door is closed again, the remain-
ing exit time is cancelled.

Bell/Siren Sounds After Away Arming

Audible Exit Fault

In an attempt to reduce false alarms, the Audible Exit Fault is designed to notify you of an improper
exit when arming the system. In the event that you fail to securely close the Exit/Entry door during
the allotted exit delay period, the system will sound the alarm to indicate an improper exit. 
Your installer will tell you if this feature has been enabled on your system. If this occurs:
1. Re-enter the premises.
2. Enter your [access code] to disarm the system. You must do this before the entry delay timer 

expires.

3. Follow the Away arming procedure again, ensure that the entry/exit door(s) are secured.

Arming Error

An error tone will sound if the system is unable to arm. This will happen if the system is not ready to
arm (i.e. sensors are open), or if an incorrect user code has been entered. If this happens, ensure all
sensors are secure, press 

 and try again. 

Disarming

Enter your access code to disarm anytime the system is armed (Armed (

) indicator is on). The key-

pad will sound a continuous tone after the entry delay has been initiated by opening the entry/exit
door. Enter your code within _____ seconds to avoid an alarm condition (check with your installer to
have this time programmed).

Disarming Error

If your code is invalid, the system will not disarm and a 2-second error tone will sound. If this hap-
pens, press 

 and try again. 

Summary of Contents for PowerSeries SCW9045-433

Page 1: ...ss Alarm System v1 0 WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual...

Page 2: ...stics 757 Douglas Hill Rd Lithia Springs GA 30122 Additional Information Connection to party line service is subject to state tariffs Contact the state public utility commission public service commiss...

Page 3: ...m Sounds 4 Intrusion Burglar Alarm Continuous Siren 4 Fire Alarm Pulsed Siren 4 2 Way Audio Audio Operation SCW9047 only 4 Time Date Programming 4 Bypassing Zones 4 Trouble Conditions 6 Alarm Memory 6...

Page 4: ...se by wiping with a damp cloth only DO NOT use abrasives thinners solvents or aerosol cleaners spray polish that may enter through holes in the enclosure case of the Alarm Controller and cause damage...

Page 5: ...efore it becomes functional NOTE This system has a communicator delay of 30 seconds It can be removed or it can be increased up to 45 seconds by the installer NOTE Ensure that your Installer verifies...

Page 6: ...bypass the interior protection i e motion sensors and arm the perimeter of the sys tem i e doors and windows Close all sensors i e stop motion and close doors The Ready indicator should be on Press an...

Page 7: ...tem is installed in accordance with SIA CP 01 Standard for False Alarm Reduction then the violation restoral followed by a second violation of the entry exit zone before the end of the exit delay will...

Page 8: ...signal will be transmitted to the Central Station and the alarm system will also annunciate that the cancel signal was transmitted Call your central station to avoid a dispatch Fire Alarm Pulsed Siren...

Page 9: ...eturn to the Ready state press Activating All Bypassed Zones To remove bypass all zones 1 Press then your access code if necessary 2 Press 3 To exit bypassing mode and return to the Ready state press...

Page 10: ...e Entry Exit Beeps To turn the door chime function on or off press and hold the Chime key for 2 seconds or press Trouble Condition Comments Action Service Required Press 1 for more information Indicat...

Page 11: ...lease see below for details Duress Codes Duress codes are standard User Codes that will transmit the Duress Reporting Code whenever the code is entered to perform any function on the system Any User C...

Page 12: ...Communicator are tested 5 Enable DLS Allow Remote System Service If enabled the installer will be able to access Installer Programming remotely using DLS Downloading Software This function provides a...

Page 13: ...ess Walk Test Walk Test mode allows you test the operation of each detector in the system While in Walk Test mode the Ready Armed and Trouble LED s will flash to indicate that the Walk Test is active...

Page 14: ..._____ Installer Information Company ___________________ Telephone __________________ If you suspect a false alarm signal has been sent to the central monitoring station call the station to avoid an un...

Page 15: ...11 Sensor Zone Information Sensor Protected Area Sensor Type Sensor Protected Area Sensor Type 01 18 02 19 03 20 04 21 05 22 06 23 07 24 08 25 09 26 10 27 11 28 12 29 13 30 14 31 15 32 16 33 17 34...

Page 16: ...Consult National Fire Alarm Code NFPA 72 CAN ULC S553 M86 or other appro priate national standards for installation recommendations Do not locate smoke detectors at the top of peaked or gabled ceilin...

Page 17: ...indows are easily opened Ensure that they are not painted shut and that their locking mechanisms operate smoothly If opening or using the exit is too difficult for children the elderly or handicapped...

Page 18: ...14...

Page 19: ...NOTES...

Page 20: ...reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detectors such as when the fire is in a chimney walls or roof...

Reviews: