4

Remote Arming and Disarming

The system can be armed and/or disarmed (if programmed by the installer) using a remote control
device (wireless key). When arming the system by using the Arm button on the wireless key, the system
will acknowledge the command by sounding a single bell squawk  and when disarming using the Dis-
arm button on the wireless key the system will acknowledge the command by sounding two bell
squawks . Three squawks heard when disarming with the disarm button indicates that that an alarm
occurred while the system was armed. If you are unsure of the cause of the alarm, proceed with cau-
tion.

Emergency Keys

Press the 

 (

F

),  

(

A

) or 

 (

P

) key for 2 seconds to generate a Fire, Auxiliary or Panic alarm. The

keypad sounder will beep indicating that the alarm input has been accepted and transmission to the
central station is underway. The 

 (

P

) key may or may not sound the bell depending on Installer

setup.

NOTE: The Fire keys can be disabled by the installer. 

When Alarm Sounds

The system can generate 2 different alarm sounds:

• Continuous Siren = Intrusion (Burglary Alarm)
• Temporal / Pulsed Siren = Fire Alarm

Intrusion (Burglary) Alarm Continuous Siren

NOTE: If you are unsure of the source of the alarm, proceed with caution! If the alarm was 
accidental, enter your Access Code to silence the alarm. If the alarm system is disarmed within the 
programmed Abort Window (check with the installer if this option has been enabled on your system 
and what is the transmitter delay time programmed), no alarm transmission to the Central Station 
will occur. Starting at the end of the Abort Window there is a five minute Cancel window, during 
which a user can cancel, by entering his access code, an alarm that has been previously transmitted. 
A cancel signal will be transmitted to the Central Station and the alarm system will also annunciate 
that the cancel signal was transmitted. Call your central station to avoid a dispatch.

Fire Alarm Pulsed Siren

 Follow your emergency evacuation plan immediately! 

If the fire alarm was accidental (i.e. burned toast, bathroom steam, etc.), enter your Access Code to
silence the alarm. Call your central station to avoid a dispatch.

2-Way Audio Operation (SCW9047 only)

If programmed by the installer, this feature allows the monitoring station to initiate a 2-way audio
session when an alarm has been received. This feature is used to verify the nature of the alarm or
determine the type of assistance required by the occupant. 

NOTE: This feature can be initiated only by the monitoring station after an alarm has been 
received. The user can not initiate a 2-way audio session.

Time & Date Programming

Press 

 plus your Master Access Code to enter User Functions. Use the 

 

scroll keys to find

the menu option then press 

 

to select it. Enter the time in 24-hr. format (HH:MM), followed by the

date (MM:DD:YY). Press 

 to exit programming. If you are viewing a ‘Loss of Clock’, trouble from

within the trouble menu (

), press 

 to directly enter Date and Time programming. See Trou-

ble Conditions on page 6), 

NOTE: Your installer may have programmed your system to display the time and date while the key-
pad is idle. Press the

 

 key to clear the date and time display if desired.

Bypassing Zones

Use the zone bypassing feature when you need access to a protected area while the system is armed,
or when a zone is temporarily out of service, but you need to arm the system. Bypassed zones will
not be able to sound an alarm. Bypassing zones reduces the level of security. If you are bypassing a
zone because it is not working, call a service technician immediately so that the problem can be
resolved and your system returned to proper working order. Ensure that no zones are unintentionally

Summary of Contents for PowerSeries SCW9045-433

Page 1: ...ss Alarm System v1 0 WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual...

Page 2: ...stics 757 Douglas Hill Rd Lithia Springs GA 30122 Additional Information Connection to party line service is subject to state tariffs Contact the state public utility commission public service commiss...

Page 3: ...m Sounds 4 Intrusion Burglar Alarm Continuous Siren 4 Fire Alarm Pulsed Siren 4 2 Way Audio Audio Operation SCW9047 only 4 Time Date Programming 4 Bypassing Zones 4 Trouble Conditions 6 Alarm Memory 6...

Page 4: ...se by wiping with a damp cloth only DO NOT use abrasives thinners solvents or aerosol cleaners spray polish that may enter through holes in the enclosure case of the Alarm Controller and cause damage...

Page 5: ...efore it becomes functional NOTE This system has a communicator delay of 30 seconds It can be removed or it can be increased up to 45 seconds by the installer NOTE Ensure that your Installer verifies...

Page 6: ...bypass the interior protection i e motion sensors and arm the perimeter of the sys tem i e doors and windows Close all sensors i e stop motion and close doors The Ready indicator should be on Press an...

Page 7: ...tem is installed in accordance with SIA CP 01 Standard for False Alarm Reduction then the violation restoral followed by a second violation of the entry exit zone before the end of the exit delay will...

Page 8: ...signal will be transmitted to the Central Station and the alarm system will also annunciate that the cancel signal was transmitted Call your central station to avoid a dispatch Fire Alarm Pulsed Siren...

Page 9: ...eturn to the Ready state press Activating All Bypassed Zones To remove bypass all zones 1 Press then your access code if necessary 2 Press 3 To exit bypassing mode and return to the Ready state press...

Page 10: ...e Entry Exit Beeps To turn the door chime function on or off press and hold the Chime key for 2 seconds or press Trouble Condition Comments Action Service Required Press 1 for more information Indicat...

Page 11: ...lease see below for details Duress Codes Duress codes are standard User Codes that will transmit the Duress Reporting Code whenever the code is entered to perform any function on the system Any User C...

Page 12: ...Communicator are tested 5 Enable DLS Allow Remote System Service If enabled the installer will be able to access Installer Programming remotely using DLS Downloading Software This function provides a...

Page 13: ...ess Walk Test Walk Test mode allows you test the operation of each detector in the system While in Walk Test mode the Ready Armed and Trouble LED s will flash to indicate that the Walk Test is active...

Page 14: ..._____ Installer Information Company ___________________ Telephone __________________ If you suspect a false alarm signal has been sent to the central monitoring station call the station to avoid an un...

Page 15: ...11 Sensor Zone Information Sensor Protected Area Sensor Type Sensor Protected Area Sensor Type 01 18 02 19 03 20 04 21 05 22 06 23 07 24 08 25 09 26 10 27 11 28 12 29 13 30 14 31 15 32 16 33 17 34...

Page 16: ...Consult National Fire Alarm Code NFPA 72 CAN ULC S553 M86 or other appro priate national standards for installation recommendations Do not locate smoke detectors at the top of peaked or gabled ceilin...

Page 17: ...indows are easily opened Ensure that they are not painted shut and that their locking mechanisms operate smoothly If opening or using the exit is too difficult for children the elderly or handicapped...

Page 18: ...14...

Page 19: ...NOTES...

Page 20: ...reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detectors such as when the fire is in a chimney walls or roof...

Reviews: