High Speed Door Servo Control System
11
┆
┆
------1.Parameter
Index Parameter
Value
Default
1 Opening
Speed
10-125
100
2 Closing
Speed
10-125
80
3
Open Slowdown dis.
30-70
50
4
Close Slowdown dis.
30-70
50
5 Auto
Closing
Time
●
Disable
●
1-120 s
5 s
6 Output
1
Config
●
Non-close Limit
●
Close Limit
●
Non-open Limit
●
Open Limit
●
Opening
●
Closing
●
Non-limit Position
●
Limit Position
●
Reach Close Limit
●
Failure Warning
●
Disable
●
Double Interlock
Automatic Opening
●
Running
●
Stopped
●
Auto Mode State
●
E-Stop State
●
Auto Closing Countdown
●
Delayed Opening
Countdown
●
Partial Open Limit
●
All Open Limit
●
Safety 1 Output
●
Safety 2 Output
Disable
7 Output
2
Config
Disable
8
Safety 1 Height
Set the current position of
the door to the failure
height of safety signal 1
9
Safety 2 Height
Set the current position of
the door to the failure
height of safety signal 2
10 Partial
Opening
10-100%
100
11 Display
Config
●
Position
●
Speed
●
Torque
Torque
12 Backlight
Setting
●
3 minute auto Off
3 minute auto Off