Advanced RF Technologies, Inc.
19
3.2
Cable Connection
3.2.1
AC Power
The AC Terminal is located at the bottom of the wiring compartment on the opposite side of the wiring
compartment door. The repeater and has a free-voltage range input of 100-240V AC. The AC terminal box can
support a max gauge of 12AWG and should be connected to the breaker box on its own circuit.
Figure 3-2
AC Terminal
Figure 3-3
AC On/Off Switch
The AC Power on/off switch is on the left-hand side of the PSU which is located inside of the repeater.
AC On/Off switch