- Uplink AGC Level
Epoch-III-P8024NM: 0 to 24 dBm @ 0.5 dB step, default value: 24 dBm
Epoch-III-P8030NM: 0 to 30 dBm @ 0.5 dB step, default value: 30 dBm
Epoch-III-P8037NM: 0 to 37 dBm @ 0.5 dB step, default value: 37 dBm
Î
- Uplink Tracking Offset (0 to 10 dB @ 0.5 dB step, default value: 3 dB)
System
-
If you click the
Reboot
button, the following message box will appear:
When the system reboots, the latest settings will be saved.
Please wait approximately 30 seconds to 1 minute for the system to reboot.
-
If you click the
Factory Setting
button, the following message box will appear:
Factory setting will erase the saved settings by the user and change all the
parameters to the factory default settings.
Heartbeat Time
- Heartbeat on and off (Default mode is On)
- Heartbeat periodic time (Range: 1 to 59 min @ 1 min step,
default period is 20 min)
Alarm Setting
- RSSI Alarm at Donor (-100 ~ -50 dBm @ 0.5 dB step, default value: -85 dBm)
- RF Power Alarm (2 ~ 10 dB @ 0.5 dB step, default value: 6 dB)