This UPS has been designed and constructed to protect your assets from the wide 

range of power aberrations experienced on Utility power lines today.    It is your 
insurance for reliable, clean and stable voltage supply.    It is important to install the 
system correctly and to have it maintained correctly by your local distributor.   

Chapter 1.  IMPORTANT SAFETY 

INSTRUCTIONS 

 WARNING: 

This is a Class A-UPS Product and may cause radio interference to other home 
appliances. User are advised to take additional measures and check with their local 
distributor if in doubt. 

SAVE THESE INSTRUCTIONS

 

 

 

 

This manual contains important instructions that should be followed during 
installation and maintenance of the UPS and batteries. 

 

Servicing of Batteries Should be Performed or Supervised by Trained Personnel with 

Knowledge of Batteries and the Required Precautions   

 

 

When Replacing Batteries, Replace With the Same Quantity, Type & Capacity. 

An Important Notice 

 

CAUTION – Do Not Dispose of Battery or Batteries in an open fire. The Battery May 

Explode. 

 

 

To ensure safety in all applications where a UPS is hard wired to the Electrical Supply, 
ensure that the system is installed by a Qualified Electrical Contractor.   

 

CAUTION – Do not open or mutilate the batteries. The electrolyte from the batteries is 

toxic and harmful to the skin and eyes.   

 

The UPS systems which are supplied with a factory input plug can be safely connected 
to the wall receptacle by the user.   

 

CAUTION – Risk of Electric Shock – Battery Circuit is not isolated from AC, hazardous 

Voltage may exist between battery terminals and ground. Test before touching with 
bare hands. 

 

This UPS is connected to an internal/external battery bank. There will be voltage at the 

output terminals if the UPS is turned on even if the input AC Mains is not available.   

 

CAUTION – A Battery can present a Risk of Electrical Shock and High Short Circuit 

Current.    The Following Precaution Should be Observed When Working on Batteries: 

 

Make sure that the AC Utility outlet is correctly grounded.   

 

Do not try to repair the unit yourself, contact your local supplier or your warranty will be 

void.  

A.  Remove watches, rings, or other metal objects. 
B.  Use tools with insulated handles. 

 

Please make sure that the input voltage of the UPS matches the supply voltage.   

C.  Wear rubber gloves and boots. 
D.  Do not lay tools or metal parts on top of batteries. 

 

Use a certified input power cable with the correct plugs and sockets for the appropriate 

voltage system.   

E.  Disconnect charging source prior to connecting or disconnecting battery terminals. 

 

CAUTION – To reduce the risk of fire, connect only to a circuit provided with 50 

amperes maximum branch circuit over-current protection in accordance with 
the National Electric Code, ANSI/NFPA 70.( 3KRT) 

 

To eliminate any overheating of the UPS, keep all ventilation openings free from 

obstruction and do not place any foreign objects on top of the UPS. Keep the UPS   

20 cm away from the wall.   

 

Make sure the UPS is installed within the proper environment as specified. (0-40

°

C and 

30-90% non-condensing humidity) 

 

Do not install the UPS under direct sunlight.    Your warranty will be void if the batteries 

fail due to overheating. 

 

This UPS system is designed for indoor use only. 

 

This UPS system is not design for use in dusty, corrosive and salty environments .   

 

The warranty for this UPS will be void if water or other liquid is spilt or poured directly 

onto the UPS. Similarly we do not warrant any damage to the UPS if foreign objects are 
deliberately or accidentally inserted into the UPS enclosure.   

 

The battery will discharge naturally if the system is unused for a period of time. 

 

It should be recharged every 2-3 months if unused. If this is not done, then the 

  warranty will be null and void.    During normal operation, the batteries will be   

automatically remained in charged condition.   

 

This UPS supports electronic equipment in offices, telecommunication, process control, 

medical and security applications. 

 

 

3

Summary of Contents for Mini-J RT series

Page 1: ...stallation 14 4 3 2 Rack Mount installation 16 4 4 Operation Test 18 4 5 Storage Instruction 19 4 6 SNMP Slot 19 4 7 Replacing the Battery 20 Chapter 5 UPS Working Principle 22 5 1 When Utility is Normal 22 5 2 When Utility is Abnormal 22 5 3 Overload Condition 23 5 4 Inverter Failure 24 5 4 1 Output short circuit under inverter mode 24 5 4 2 Output Short circuit under bypass Mode 24 5 5 Inverter ...

Page 2: ...uit Current The Following Precaution Should be Observed When Working on Batteries Make sure that the AC Utility outlet is correctly grounded Do not try to repair the unit yourself contact your local supplier or your warranty will be void A Remove watches rings or other metal objects B Use tools with insulated handles Please make sure that the input voltage of the UPS matches the supply voltage C W...

Page 3: ...utomatically switch to bypass mode when the connected loads exceeds 120 of rating It will automatically switch back to inverter mode once overload condition ceases z Guarantees an exclusive protection against DC damage for inductive load Such as motor based devices allowing wide range of different applications Should the output becomes short circuited the UPS holds the system with current limits a...

Page 4: ...required To press the button over 5 seconds the UPS will be switched to Bypass mode and vice versa c To illustrate the percentage of output load level at AC Mode and the battery energy level at Backup Mode 4 Fault LED Red LED lights up if UPS is faulty 5 Bypass LED Amber LED lights up when UPS is in Bypass mode 6 Utility LED a AC normal Green LED lights up b 100 for load battery level 7 Inverter L...

Page 5: ...e installation This is to be plugged by the devices to be protected by the UPS Socket type 1Kva 2Kva 3Kva NEMA 5 15R 4pcs 2pcs N A NEMA 5 20R N A 2pcs N A NEMA L5 30 N A N A 1pce AC Outlet For 120Vac System Terminal Block N A N A Yes Socket Type 1Kva 2Kva 3Kva IEC 3pcs 3pcs N A Local Sockets 1pce 2pcs 2pcs 4 For 230Vac System Terminal Block N A N A Yes 5 SNMP Slot It is an optional feature used fo...

Page 6: ...tware kit The bundled software of the UPS is for Windows environment such as Windows 3 1 Windows 95 98 Windows NT For other applications such as Novell NetWare Unix etc please contact your local distributor for appropriate solution 3 3 1 RS232 interface settings The RS232 interface is to be configured as follows Baud Rate 2400 bps Data Length 8 bits Stop Bit 1 bit Parity None 3 3 2 Pin Assignments...

Page 7: ...m 2 Remove the packing materials Note The UPS module is approx 12 5 39 kgs be cautious when unpacking and lifting the unit to avoid injury 2 Do not block the air flow to the ventilation openings of the unit 3 Standard Package includes a User s Manual b AC Input Power Cord Not available for hard wiring connection models c IEC output cables for the UPS with IEC sockets only d RJ11 Phone Jack Cable e...

Page 8: ...Use with extended battery bank 4 3 Installation Instructions Step 1 4 3 1 Tower installation Stand alone unit Step 1 Step 2 15 Step 2 14 ...

Page 9: ...Step 4 4 3 2 Rack Mount installation Step 1 Step 2 Step 3 Step 5 17 16 ...

Page 10: ... then the Utility LED and Inverter LED will light up simultaneously 5 Simulate a Mains failure by disconnecting the input power cord of the UPS to see whether the UPS remains operation DC Mode when Utility is absent The Utility LED should extinguish and the alarm will sound continuously till battery cut off The UPS should continue to provide power supply at its output terminals To mute the audible...

Page 11: ...Step 2 4 7 Replacing the Battery Step 1 Step 3 Step 4 20 21 ...

Page 12: ... abnormal condition is illustrated as follows O P OUTPUT 4 1 RECTIFIER O P OUTPUT 4 2 23 During a blackout the UPS will work as illustrated in figure 4 2 When Battery is low buzzer will beep continuously till battery is completely cut off The battery low protection of the UPS will cut off battery supply after a preset threshold to avoid the battery from over drain The Inverter LED and Bat Low LED ...

Page 13: ...Output Voltage Out of tolerance If the UPS inverter delivers over current and out of tolerance voltage to its output the UPS is out of order The UPS will switch to bypass mode when Utility is normal The Utility LED Bypass LED and Fault LED will light up If these two conditions occur when Utility is abnormal the UPS will turn off the Output and the Fault LED will light up O P OUTPUT 4 4 25 2 Troubl...

Page 14: ...ging capability test 27 Bun ftwa allation allation 1 Connect the male connector of RUPS II cable 2 Connect the female connector of RUPS II cabl rt If there is only a DB25 connector of the RS232 p DB9 DB25 adapter to convert it 7 2 Software Installation tallatio A RUPS II for MS DOS 1 Insert the system diskett sk execute INSTALL EXE u A CD DOS Enter TALL 2 Please select the MS DO t 3 And create the...

Page 15: ...1 Login the File Server as a SUPERVISOR or a USER with Access Right sub directory SYS SYSTEM F LOGIN SUPERVISOR mv linux z linux Z or mv LINUX Z linux Z chmod 755 install 2 Insert the system diskette into the floppy disk Driver A or you drive 4 Execute the installation program install Select a targ 5 sure no other process using the sam lau UPSilon for Unix daemon p nch the 3 Execute INSTALL EXE in...

Page 16: ...uit a Inv UPS shut nd Cut the O b ode ks do Mode Bypass M down a AC Input fuse Brea utput wn Overheat a Utility Normal Switch to Bypass sounds continuously cut the output b Utility Abnormal Buzzer t LED lights up then Faul H ode igh Voltage ff Trip O Switch to Backup M Battery Low Alarm continuously till battery cutoff Noise Suppression Comply with EN50091 2 Spike Suppression N6100 Comply with E 0...

Reviews: