2.2. Advanced Technical Characteristics
Chapter 2. Product Introduction
z
Innovative light weight and compact design for modern OA environment and
OEM flexibility.
z
Powerful CPU integrates all power stages, control and communication
functions for maximum UPS performance; Including Power management
status monitoring, configuration setting, operation Scheduling, remote control
and self-diagnostic capability.
2.1. General Characteristics
•
True online, Double Conversion architecture continuously supplies to your
critical device with a stable, regulated, transient-free pure sine-wave AC
Power.
z
Advanced digital communication capability allows full function remote control
from any computer environment via standard RS-232 interface using
Megatec’s RUPSII protocol.
•
50KHz PWM sine-wave topology yields an excellent overall performance.
z
State-of-the-Art
IGBT
Technology ensures highest efficiency and reliability
under worst operating condition.
•
The high crest factor of the inverter handles all high-inrush current loads
without a need to upgrade the power rating.
z
Industry leading Inverter protection technology incorporates 2-stage output
Current sensor, smart overload output current control, improved crest factor,
and feedback failure proof circuit, elevating the availability of power service.
•
To protect the unit from overloading, the UPS will automatically switch to
bypass mode when the connected loads exceeds 120% of rating. It will
automatically switch back to inverter mode once overload condition ceases.
z
Guarantees an exclusive protection against DC damage for inductive load,
Such as motor based devices, allowing wide range of different applications.
•
Should the output becomes short-circuited, the UPS holds the system with
current limits and supplies to the output automatically till the short circuit
situation is cleared.
z
Advanced Input Power Factor Correction (PFC) capability guarantees near
unity PF for maximum energy efficiency
•
Should the unit become overheated, the internal thermistor will detect
the over temperature and switches to bypass mode and returns to Inverter
mode when the temperature returns to normal .
z
Unique electronic over-current protection detects output short-circuit and faults,
and halts output before damaging to output fuse or equipment, minimizing the
need for service.
•
Maintenance-free sealed-type battery minimizes after-sales service.
z
Wide input voltage working range minimizes battery usage and enhances
battery life.
z
Automatic Frequency Sensor enables automatic synchronization during
frequency shift.
z
DC-start function ensures possible start-up of UPS during power outages.
z
Self-diagnostics function ensures UPS reliability and availability.
z
Built-in supplementary charger enables speediest charging of external battery
Bank.
z
Optional SNMP adapter provides possible solution to achieve direct power
management via internet protocol.
4
5