background image

Document Part Number: 4702572-002

Document Revision: B

     
   

Series 4000

Installation Guide

Backup Battery Option Kit

Instructions for installing the optional backup battery in the 

Series 4000 badge timeclock

®

Summary of Contents for 40000 Series

Page 1: ...Document Part Number 4702572 002 Document Revision B Series 4000 Installation Guide Backup Battery Option Kit Instructions for installing the optional backup battery in the Series 4000 badge timeclock ...

Page 2: ... Adaptive Server is a trademark of Sybase Inc iSeries and WebSphere are trademarks and AIX AS 400 and IBM are registered trademarks of International Business Machines Corporation Lotus and 1 2 3 are registered trademarks of Lotus Development Corporation Carbon Copy and OpenVMS are trademarks of Compaq Computer Corporation pcAnywhere is a trademark of Symantec Corporation Cognos Impromptu and Power...

Page 3: ...nce with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio and television reception Canadian DOC Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Depa...

Page 4: ......

Page 5: ...ged from use allow 24 hours for the timeclock to recharge the battery When the Series 4000 timeclock is on AC power the amber power LED the bottom LED in the upper right corner of the timeclock lights steadily when the timeclock is on backup battery power the amber power LED blinks Warning The type of lead acid battery used in the Series 4000 timeclock can generate hundreds of amperes for short pe...

Page 6: ... Your installation scenario Instructions to follow You are about to install the Series 4000 timeclock to include the backup battery 1 Follow the instructions in the Series 4000 Badge Timeclock Installation Guide that shipped with the timeclock until it refers you to this Backup Battery Option Kit Installation Guide 2 Follow the instructions in this guide starting with Installing the Backup Battery...

Page 7: ...imeclock 3 Disconnect the transformer in the timeclock from the AC power source Depending on how you installed the timeclock do one of the following Unplug the power cord from an AC outlet external to the timeclock If the timeclock is mounted over an AC outlet unplug the power cord from that outlet If you used the internal AC outlet unplug the power cord from the internal outlet 4 Disconnect the t...

Page 8: ...freeing the cable from the routing channel in the timeclock b Carefully lift the transformer up and out from behind the wire transformer clip and out of the timeclock 6 Remove the wire transformer clip see the following illustration from the base so that you have room to install the backup battery Do this by squeezing both sides of the clip until you can lift it from the base ...

Page 9: ...m the following steps Otherwise proceed to Installing the Backup Battery Option beginning on page 8 a Disconnect the battery charger board from the timeclock s main board b Trace the wires back to the charger board freeing them from the hooks molded into the base of the timeclock Number Description 1 Battery charger board cable 2 Charger board connection to the main board ...

Page 10: ...charger board from the positive and negative terminals of the backup battery d Loosen the screw in the center of the battery charger board and remove the board from the timeclock Number Description 1 Hooks molded into the base 2 Negative terminal connection black 3 Positive terminal connection red Mlinst38 ...

Page 11: ... Battery Installation Backup Battery Option Kit Installation Guide 7 e Remove the battery from the base of the timeclock You are now ready to install the new backup battery Proceed to Installing the Backup Battery Option beginning on page 8 Mlinst39 ...

Page 12: ...net cable is not shown The illustrations also show the timeclock mounted to cover an AC outlet However this procedure applies to all power source scenarios 1 If you are installing the Series 4000 timeclock and have mounted the base to the wall perform this step If you are adding or replacing the backup battery in your installed timeclock go to step 2 Remove the wire transformer clip from the base ...

Page 13: ... Backup Battery Option Kit Installation Guide 9 2 Position the battery in the base of the timeclock as shown Number Description 1 Negative battery terminal black 2 Positive battery terminal red 3 Molded hooks to hold the battery in place ...

Page 14: ...the timeclock base as shown in the following illustration Squeeze the clip to lock it into position under the two molded hooks in the base 4 Plug the cables that came with the battery into the connectors on the charger board Match the ends of each cable with the pin connectors on the board ...

Page 15: ...and secure it with the supplied screw 6 Connect the charger board to the positive and negative terminals of the backup battery Use the hooks molded into the base of the timeclock to secure the cable along its route Number Description 1 Cable routing hooks 2 Negative terminal connection black 3 Positive terminal connection red ...

Page 16: ...anently attached cable is facing down b Route the transformer cable cable coming from the bottom of the transformer back to its connection on the main board inside the cover of the timeclock c Connect the transformer cable to the main board d Plug the power cord into the top of the transformer 8 Connect the battery charger board to the timeclock s main board See the following illustration 9 Plug t...

Page 17: ...kup Battery Option Kit Installation Guide 13 What To Do Next To continue assembling the timeclock return now to the Series 4000 Badge Timeclock Installation Guide and continue with Installing the Transformer in Chapter 2 ...

Page 18: ...What To Do Next 14 ADP Inc ...

Reviews: