RK3000 High Frequency Power Supply
Operating Manual
Page 33 of 73
If the operating value is to be changed, simply press the numeric keys corresponding to
the new value (the old value will be overwritten) and press ENTER. If the present
operating value is acceptable, simply press ENTER without making any changes.
Press the
or
keys to view more prompt screens or press ESC to return the display to
either the Electrical Reading Screen or the Device Status Screen depending on the
screen you were in prior to pressing the PROMPT key.
Conduction Display
Press the PROMPT key and then the DOWN
key until the “Conduction Display” Prompt
Screen appears
Press ENTER and the “Conduction Display” Parameter Screen will appear.
The Conduction Display screen is used to view the relative on-time of the firing pulse,
from 0 to 100%. If the operating mode is to be changed, simply press the 0 or 1 key
corresponding to the new mode (the old value will be overwritten) and press ENTER. If
the present operating mode is acceptable, simply press ENTER without making any
changes. If (1) enable was selected, the Electrical Reading Screen will show the firing
on-time percentage in the mode area.
To return the Electrical Reading Screen to “normal” return to the Conduction Display
Prompt Screen and disable the conduction display mode.
Press the DOWN or UP keys to view more prompt screens or press ESC to return the
display to either the Electrical Reading Screen or the Device Status Screen depending on
the screen you were in prior to pressing the PROMPT key.
Spark Rate Control
Press the PROMPT key and then the DOWN key un
til the “Spark Rate Control” Prompt
Screen appears.
RED-01
Conduction Display
RED-01
Conduction Display
0=Disable, 1=Enable
Enter: 0
RED-01
205 V 158 A 026 kW
56kV1 00kV2 1885mA
000sp 000ar 99%
RED-01
Spark Rate Control