RK3000 High Frequency Power Supply
Operating Manual
Page 30 of 73
If the operating value is to be changed, simply press the numeric keys corresponding to
the new value (the old value will be overwritten) and press ENTER. If the present
operating value is acceptable, simply press ENTER without making any changes. The
screen will now revert to either the Device Status Screen or the Electrical Reading Screen
depending which screen was active when the PED key was pressed.
QUENCH
Press the QUENCH key. The Quench Time display appears.
The acceptable range for the Quench time is presented to the right of the word “Range.”
In this example, the range is 1 to 9 Cycles. For this function a cycle is defined as 10
milliseconds in length.
The present operating value for the Quench time is presented to the right of the word
“Enter.” In this example the present operating value is 4 cycles.
If the operating value is to be changed, simply press the numeric key corresponding to
the new value (the old value will be overwritten) and press ENTER. If the present
operating value is acceptable, simply press ENTER without making any changes. The
screen will now revert to either the Device Status Screen or the Electrical Reading Screen
depending which screen was active when the PED key was pressed.
PROMPT
Pressing this key brings up the Prompt screen that allows additional parameters to be
viewed and programmed. See Programming Prompt Key Parameters that follows this
section.
Clear Alarm
Pressing this key from the Device Select, Status Screen, or Electrical Reading Screen
activates the Alarm Summary Screen. This screen show which, if any, controls have an
alarm, the elapsed time since the alarm occurred, and the name of the alarm.
The
↑ and ↓ represent the UP and Down keys.
Scrolling through the alarms will show any additional alarms for a specific ID, or alarms
for other IDs.
The firs
t two numbers after the “–“ on the time line show number of days, the next six
numbers show the hours: minutes: seconds since the alarm condition has occurred.
When the cause of an alarm is repaired, it is necessary to return to the
CLEAR ALARM screen, scroll to the appropriate ID number and press the
CLEAR ALARM again to clear the alarm from the display.
Pressing the ESC key will bring you back to the previous screen.
RED -01
Quench Time
Range: 1-9 Cycles
Enter: 4
Alarm AVC-01
Time -01 18:23:37
Coordination Error
Scroll usi
ng ↑ or ↓
Enter: 400