ADOLF THIES CLIMA 4.3324.32.000 Instructions For Use Manual Download Page 2

 

 

Safety Instructions

• 

Before operating with or at the device/product, read through the operating instructions. 
This manual contains instructions which should be followed on mounting, start-up, and operation.  
A non-observance might cause: 
 

 

- failure of important functions 

 

 

- Endangering of persons by electrical or mechanical effect 

 

 

- Damage to objects 

• 

Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified technician 
who is familiar with and observes the engineering regulations, provisions and standards applicable in each case. 

• 

Repairs and maintenance may only be carried out by trained staff or 

Adolf Thies GmbH & Co. KG

. Only 

components and spare parts supplied and/or recommended by 

Adolf Thies GmbH & Co. KG

 should be used for 

repairs.  

• 

Electrical devices/products must be mounted and wired only in voltage-free state. 

• 

Adolf Thies GmbH & Co KG

 guarantees proper functioning of the device/products provided that no 

modifications have been made to the mechanics, electronics or software, and that the following points are 
observed: 

• 

All information, warnings and instructions for use included in these operating instructions must be taken into 
account and observed as this is essential to ensure trouble-free operation and a safe condition of the measuring 
system / device / product.  

• 

The device / product is designed for a specific application as described in these operating instructions. 

• 

The device / product should be operated with the accessories and consumables supplied and/or recommended 
by 

Adolf Thies GmbH & Co KG

 . 

• 

Recommendation: As it is possible that each measuring system / device / product under certain conditions, and 
in rare cases, may also output erroneous measuring values, it is recommended using redundant systems with 
plausibility checks with 

security-relevant applications

Environment 

• 

As a longstanding manufacturer of sensors Adolf Thies GmbH & Co KG is committed to the 
objectives of environmental protection and is therefore willing to take back all supplied products 
governed by the provisions of "

ElektroG

(

German Electrical and Electronic Equipment Act) 

and to perform environmentally compatible disposal and recycling. We are prepared to take 
back all Thies products concerned free of charge if returned to Thies by our customers 
carriage-paid. 

 

• 

Make sure you retain packaging for storage or transport of products. Should packaging 
however no longer be required, arrange for recycling as the packaging materials are designed 
to be recycled. 

 

Documentation 

• 

©  Copyright 

Adolf Thies GmbH & Co KG

, Göttingen / Germany 

• 

Although this operating instruction has been drawn up with due care, 

Adolf Thies GmbH & Co KG

 can accept 

no liability whatsoever for any technical and typographical errors or omissions in this document that might 
remain. 

• 

We can accept no liability whatsoever for any losses arising from the information contained in this document. 

• 

Subject to modification in terms of content. 

• 

The device / product should not be passed on without the/these operating instructions. 

 

2 - 14 

021591/02/09

 

 

Summary of Contents for CLIMA 4.3324.32.000

Page 1: ...ATA Instruction for Use 021591 02 09 Combined Wind Transmitter Output 8 Bit parallel 4 3324 32 000 001 ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone...

Page 2: ...ons The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device...

Page 3: ...tion 6 5 1 Mounting of wind vane 6 5 2 Mounting of Cup Star 7 5 3 Mounting of Wind Transmitter 7 5 4 Electrical Mounting 8 6 Maintenance 8 7 Connecting Diagrams 8 8 Technical Data 9 9 Dimensional Draw...

Page 4: ...uments are equipped with an electronically regulated heating in order to guarantee a smooth running of the ball bearings and to avoid ice formation at the slot of the outer rotation parts The electric...

Page 5: ...35 0 39 53 95 0 63 33 155 0 87 165 215 0 111 177 275 0 135 141 335 0 16 8 37 5 40 52 97 5 64 32 157 5 88 164 217 5 112 176 277 5 136 140 337 5 17 24 40 0 41 60 100 0 65 96 160 0 89 172 220 0 113 144 2...

Page 6: ...eration Remark It is advisable to attach lightning rod order no 4 3100 99 000 in areas with considerable lightning activity 5 1 Mounting of wind vane Tools Screw wrench SW 8 Mounting of wind vane 1 Re...

Page 7: ...ap until they are aligned Then select an obvious point in a northerly direction in the surroundings a tree a building etc with the aid of a compass Take a bearing on this point over the wind vane and...

Page 8: ...r and to the data logging in case the data logging or the like is on the same electrical potential The cable shield should be connected on one side only to the data logging in case there are potential...

Page 9: ...D 5366 96 with 4 3324 32 000 D 0 3 Electr output 3 1042 Hz 8 bit parallel Code Voltage supply UB 3 3 28 V DC 3 3 28 V DC Output signal unloaded ULow 1 V UHeight UB ULow 0 7V UHeight UB Output signal...

Page 10: ...9 Dimensional Drawings Figure 2 Dimension 4 3324 32 000 10 14 021591 02 09...

Page 11: ...Figure 3 Dimension 4 3324 32 001 11 14 021591 02 09...

Page 12: ...er 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 552 2004 EC Regulation EC No 552 2004 of the European Parliame...

Page 13: ...13 14 021591 02 09...

Page 14: ...IES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 14 14 02159...

Reviews: