ADOLF THIES CLIMA 4.3324.32.000 Instructions For Use Manual Download Page 12

 

10  EC-Declaration of Conformity 

Document-No.: 

000439

 Month: 

02 

Year: 

09 

Manufacturer: 

A D O L F   T H I E S   G m b H   &   C o.  K G

 

 Hauptstr. 76 
 D-37083 Göttingen        

 

 

 Tel.: (0551) 79001-0  

 Fax: (0551) 79001-65      
 email: [email protected] 

 
 
Description of Product:   

Combined Wind Transmitter 

 

Article No. 

4.3324.32.000 4.3324.32.001 4.3324.32.900  

 

4.3336.22.000 4.3336.22.001 4.3336.22.008 4.3336.32.000 

 

4.3336.32.001 4.3336.32.008  

 

 

 

 

 

 

specified technical data in the document: 

021590/02/09; 021593/02/09; 021594/02/09;

 

 
The indicated products correspond to the essential requirement of the following European Directives and Regulations: 
 
2004/108/EC DIRECTIVE 

2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL 

of 15 December 2004 on the approximation of the laws of the Member States relating to 
electromagnetic compatibility and repealing Directive 89/336/EEC 

 
2006/95/EC DIRECTIVE 

2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL 

of 12 December 2006  on the harmonisation of the laws of Member States relating to electrical 
equipment designed for use within certain voltage limits 

 
552/2004/EC 

Regulation (EC) No 552/2004 of the European Parliament and the Council of 10 March 2004  
on the interoperability of the European Air Traffic Management network  
(the interoperability Regulation) 

 
 
The indicated products comply with the regulations of the directives. This is proved by the compliance with the following 
standards: 

 

Reference number 

Specification 

 

 

IEC 61000-6-2: 2005 

Electromagnetic compatibility 
Immunity for industrial environment 

  

IEC 61000-6-3: 2006 

Electromagnetic compatibility 
Emission standard for residential, commercial and light industrial environments 

  

IEC 61010-1: 2001 

Safety requirements for electrical equipment for measurement, control and  
laboratory use.      Part 1: General requirements 

 
 
 
 
 
Place:  Göttingen                                                                Date:  12.02.2009 

 

 

This declaration certificates the compliance with the mentioned directives, however does not include any warranty of characteristics. 
Please pay attention to the security advises of the provided instructions for use. 

 

12 - 14 

021591/02/09

 

 

Summary of Contents for CLIMA 4.3324.32.000

Page 1: ...ATA Instruction for Use 021591 02 09 Combined Wind Transmitter Output 8 Bit parallel 4 3324 32 000 001 ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone...

Page 2: ...ons The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device...

Page 3: ...tion 6 5 1 Mounting of wind vane 6 5 2 Mounting of Cup Star 7 5 3 Mounting of Wind Transmitter 7 5 4 Electrical Mounting 8 6 Maintenance 8 7 Connecting Diagrams 8 8 Technical Data 9 9 Dimensional Draw...

Page 4: ...uments are equipped with an electronically regulated heating in order to guarantee a smooth running of the ball bearings and to avoid ice formation at the slot of the outer rotation parts The electric...

Page 5: ...35 0 39 53 95 0 63 33 155 0 87 165 215 0 111 177 275 0 135 141 335 0 16 8 37 5 40 52 97 5 64 32 157 5 88 164 217 5 112 176 277 5 136 140 337 5 17 24 40 0 41 60 100 0 65 96 160 0 89 172 220 0 113 144 2...

Page 6: ...eration Remark It is advisable to attach lightning rod order no 4 3100 99 000 in areas with considerable lightning activity 5 1 Mounting of wind vane Tools Screw wrench SW 8 Mounting of wind vane 1 Re...

Page 7: ...ap until they are aligned Then select an obvious point in a northerly direction in the surroundings a tree a building etc with the aid of a compass Take a bearing on this point over the wind vane and...

Page 8: ...r and to the data logging in case the data logging or the like is on the same electrical potential The cable shield should be connected on one side only to the data logging in case there are potential...

Page 9: ...D 5366 96 with 4 3324 32 000 D 0 3 Electr output 3 1042 Hz 8 bit parallel Code Voltage supply UB 3 3 28 V DC 3 3 28 V DC Output signal unloaded ULow 1 V UHeight UB ULow 0 7V UHeight UB Output signal...

Page 10: ...9 Dimensional Drawings Figure 2 Dimension 4 3324 32 000 10 14 021591 02 09...

Page 11: ...Figure 3 Dimension 4 3324 32 001 11 14 021591 02 09...

Page 12: ...er 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 552 2004 EC Regulation EC No 552 2004 of the European Parliame...

Page 13: ...13 14 021591 02 09...

Page 14: ...IES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 49 551 79001 0 Fax 49 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 14 14 02159...

Reviews: