- 23 -
-
:weight reception mode (see section
WEIGHT READING VIA SERIAL PORT
).
-
: weight reception mode (see section
WEIGHT READING VIA SERIAL PORT
).
-
: transmission speed (2400, 4800, 9600, 19200, 38400, 115200; default:
9600).
-
: instrument address (from 1 to 99; default: 1).
-
: maximum transmission frequency (10 – 20 – 30 – 40 – 50 – 60 – 70 – 80
– 100 – 200 – 300; default: 10); to be set when the
transmission protocol
is selected.
Maximum setting frequency
(
)
:
-
20 Hz with minimum baud rate 2400 baud.
-
40 Hz with minimum baud rate 4800 baud.
-
80 Hz with minimum baud rate 9600 baud.
-
100 Hz with minimum baud rate 19200 baud.
-
200 Hz with minimum baud rate 38400 baud.
-
300 Hz with minimum baud rate 38400 baud.
-
: delay in milliseconds which elapses before the instrument replies (from 0
to 200 ms; default: 0).
-
:
-
: no parity (default).
-
:
even parity.
-
: odd parity.
-
: stop bit (1 – 2; default: 1).
-
:
number of copies of the weight printout.
-
:
number of blank lines between one printout and the next
.
-
: printing of custom heading from PC (
-
:
connected printer type:
-
-
-
For more information about protocols and methods of communication, request the
proper manual to technical assistance.
ADN
Pesage
Transmetteur de pesage T16F : Manuel d’utilisation et d’installation