ADLY MOTO
13-1
ELECTRICAL DEVICE
Attention of Operation
WARNING
Κ
Ϡʳ
Battery electrolyte contains sulfuric acid, which can cause severe burns. Avoid contact of skin,
eyes, or clothing
Ϡʳ
When sulfuric acid water spill into clothing will stick to skin. Take off the clothing and flush
with water.
z
Battery can be charged and discharged. Without charging, the battery will have less lifetime.
z
If the battery have short circuit inside, both terminal will not have voltage existed. Besides, the
regulator rectifier lost the function and shorter lifetime.
z
If the battery stay too long without use, it will lost power and have less capacity. The battery
need to charge each 2~3 months.
z
After fill up the electrolyte, the new battery will generate voltage. It’s necessary to recharge if
the voltage is low. It’s necessary to leave the battery for more than 20 minutes before sealing
the cap. It will increase the lifetime of new battery if recharged before installed.
z
Do not unplug the electrical components from wire hardness when the current is working. This
will cause too high of voltage and damage other compounds such as rectifier, light bulbs…etc.
Turn off the main switch to OFF before the operation.
z
The Maintenance Free battery does not need to refill electrolyte or water.
z
All charge system needs to be installed before check.
z
Do not use quick charge unless it’s in urgent.
z
The battery needs to be taking out from vehicle when doing charge work.
z
When checking the voltage, must use the electrical meter.
Diagnosis of troubles
No Electrical Power
x
Over discharged of the battery
x
Wire hardness did not connected to
the
battery
x
Fuse
broken
x
Main switch defect
Low Voltage
x
Battery charges insufficient
x
Bad
connection
x
Regulator
rectifier
defect
No Continues Current
x
Bad contact of battery with main wire
hardness
x
Bad connection of charge system
x
Bad contact of the lighting system
cause
short
circuit
Charge System no function
x
Bad connection of the wire hardness
connectors
x
Main wire hardness broken or
short-circuit
x
Regulator
rectifier
defect
x
AC Generator defect
x
Fuse
broken