ADLINK Technology Inc.
LEC-
PX30 User’s Guide
Page 36
copyright © 2020 ADLINK Technology Inc.
4.3.16
Power and System Management
Name
Pin
#
Description
I/O
Type
I/O
Level
Power
Domain
PU /
PD
Comments
BATLOW#
S156 Battery low indication to Module. Carrier to float
the line in inactive state.
I OD
CMOS
TBD
Runtime
PU 4.7K
Driven by OD on Carrier.
Pulled up on module.
CARRIER_PWR_ON S154 Carrier board circuits (apart from power
management and power path circuits) should not
be powered up until the Module asserts the
CARRIER_PWR_ON signal.
O
CMOS
TBD
-
On x86 designs this pin should utilize
the RSM_RST# signal.
CARRIER_STBY#
S153 The Module shall drive this signal low when the
system is in a standby power state.
O
CMOS
TBD
-
On x86 designs this pin should utilize
the SUS_S3# signal.
CHARGER_PRSNT# S152 Held low by Carrier if DC input for battery charger
is present.
I OD
CMOS
TBD
Standby
PU
100K
Driven by OD on Carrier.
Pulled up on module.
CHARGING#
S151 Held low by Carrier during battery charging.
Carrier to float the line when charge is complete.
I OD
CMOS
TBD
Standby
PU 68K
Driven by OD on Carrier.
Pulled up on module.
VIN_PWR_BAD#
S150 Power bad indication from Carrier board. Module
and Carrier power supplies (other than Module
and Carrier power supervisory circuits) shall not be
enabled while this signal is held low by the Carrier.
I OD
CMOS
TBD
Standby
PU 10K
Driven by OD on Carrier
Module must implement PU but
actual value is depended on particular
module design.
SLEEP#
S149 Sleep indicator from Carrier board. May be
sourced from user Sleep button or Carrier logic.
Carrier to float the line in in-active state.Active low,
level sensitive. Should be de-bounced on the
Module.
I OD
CMOS
TBD
Standby
PU 4.7K
Driven by OD on Carrier.
Pulled up on module.
LID#
S148 Lid open/close indication to Module. Low indicates
lid closure (which system may use to initiate a
sleep state). Carrier to float the line in in-active
state. Active low, level sensitive. Should be de-
bounced on the Module.
I OD
CMOS
TBD
Standby
PU 4.7K
Driven by OD on Carrier.
Pulled up on module.
POWER_BTN#
P128 Power-button input from Carrier board. Carrier to
float the line in in-active state. Active low, level
sensitive. Should be debounced on the Module.
I OD
CMOS
TBD
Standby
PU 10K
Driven by OD on Carrier.
Pulled up on module.