![ADLINK Technology NuDAQ User Manual Download Page 63](http://html.mh-extra.com/html/adlink-technology/nudaq/nudaq_user-manual_2852695063.webp)
Register Format
51
Interrupt Status, COS INT Control Read Back Registers
When any COS interrupt occurs, these registers provide informa-
tion to recognize the interrupt status and the interrupt setup condi-
tion read back.
Address: BASE+0x06h
Reset Value: 0x0000h
Read/Write: R
--
--
--
--
C3IS
C2IS
C1IS
C0IS
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
COS0E
--
--
--
--
--
--
--
Bit15
Bit14
Bit13
Bit12
Bit11
Bit10
Bit9
Bit8
Bit14 - 4
Not used
Bit0
CIS0: COS 0 INT Status
1: COS assert
0: COS not assert
Bit1
CIS1: COS 1 INT Status
1: COS assert
0: COS not assert
Bit2
CIS2: COS 2 INT Status
1: COS assert
0: COS not assert
Bi3
CIS3: COS 3 INT Status
1: COS assert
0: COS not assert
Bit15
COS0E: COS 0 Interrupt enable status
1: Enabled
0: Disabled