Overview
7
LEC-BTS
1.4.3
Electrical Specifications
Table 1-4 specifies the electrical characteristics of the module.
1.4.4
Power Specifications
Table 1-5 provides the power requirements for this module.
Operating configurations:
In-rush operating configuration - Typical under Windows 8.1
Idle operating configuration - Typical under Windows 8.1
Intel TAT (Thermal Analysis Tool) operating configuration - Typical under Windows 8.1
1.4.5
Environmental Specifications
Table 1-6 provides the most efficient operating and storage condition ranges required for this
module.
Table 1-4: Electrical Specifications
Parameter
Value
Voltage Input
Standard
RTC
Fixed 5-Volt Supply (+4.75V DC min to +5.25V
DC max)
3.0V, 2.0V to 3.3V (battery)
Power States
C1-C6 processor power states
S0 (active), S1 (sleep), S3 (save to RAM), S4
(suspend-to-disk), S5 (soft-off and
wake-on-LAN), and S5 ECO (wake on USB
S3/S4, WOL S3/S4/S5) system power states
Table 1-5: Power Supply Requirements
Parameter
E3815 (5W)
Characteristics
E3826 (7W)
Characteristics
E3845 (10W)
Characteristics
Input Type
Regulated DC voltage
Regulated DC voltage Regulated DC voltage
In-rush
Voltage & Current
0.55A (2.75W) @ 5V
0.65A (3.25W) @ 5V
0.85A (4.25W) @ 5V
Typical Idle
Voltage & Current
0.66A (3.30W) @ 5V
0.65A (3.25W) @ 5V
0.77A (3.85W) @ 5V
BIT*
Voltage & Current
1.18A (5.90W) @ 5V
1.60A (8.00W) @ 5V
2.52A (12.60W) @ 5V
Table 1-6: Environmental Requirements
Parameter
Conditions
Temperature
Standard
0° to +60° C (+32° to +140° F)
Extended
–40° to +85° C (–40° to +185° F)
Storage
–55° to +85° C (–67° to +185° F)
Humidity
Operating
5% to 90% relative humidity, non-condensing
Non-operating
5% to 95% relative humidity, non-condensing