background image

22

Introduction

Summary of Contents for IMB-M43

Page 1: ...Advance Technologies Automate the World Manual Rev 2 00 Revision Date Dec 31 2015 Part No 50 1X014 1000 IMB M43 ATX Intel Core i7 i5 i3 Industrial Motherboard User s Manual ...

Page 2: ...ii Revision History Revision Release Date Description of Change s 2 00 Dec 31 2015 Initial Release ...

Page 3: ...en if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the Euro pean Union s Restriction of Hazardous Substances RoHS direc tive and Waste Electrical and Electronic Equipment WEEE directive Environmental protection is a top priority for ADLINK We have enforce...

Page 4: ...NOTE NOTE Additional information aids and tips that help users perform tasks CAUTION Information to prevent minor physical injury component dam age data loss and or program corruption when trying to com plete a task WARNING Information to prevent serious physical injury component damage data loss and or program corruption when trying to complete a specific task ...

Page 5: ...anel Header 10 1 5 3 COM3 Serial Port Header 10 1 5 4 COM4 Serial Port Header 11 1 5 5 COM5 Serial Port Header 12 1 5 6 COM6 Serial Port Header 12 1 5 7 CN16 USB3 0 Header 13 1 5 8 CN14 USB2 0 Header 14 1 5 9 CN15 USB2 0 Header 15 1 5 10 CN38 Front Audio Header 15 1 5 11 FAN1 4 Pin CPU FAN Connector 17 1 5 12 FAN2 4 Pin System FAN1 Connector 17 1 5 13 FAN3 4 Pin System FAN2 Connector 18 1 5 14 CN5...

Page 6: ... A 5 1 ACPI Settings 34 A 5 2 CPU Configuration 35 A 5 3 Chipset Configuration 38 A 5 4 System Agent SA Configuration 39 A 5 5 Graphics Configuration 40 A 5 6 PCI Express Configuration 41 A 5 7 USB Configuration 45 A 5 8 USB Configuration 48 A 5 9 HD Audio Configuration 49 A 5 10 SATA Configuration 50 A 5 11 Onboard Device Configuration 51 A 5 12 Advance Power Management 54 A 5 13 AMT Configuratio...

Page 7: ...Table of Contents vii IMB M43 A 6 Security 66 A 6 1 Administrator Password 66 A 6 2 Secure Boot menu 67 A 7 Boot 68 A 8 Save Exit 70 Important Safety Instructions 73 Getting Service 75 ...

Page 8: ...viii Table of Contents This page intentionally left blank ...

Page 9: ...List of Figures ix IMB M43 List of Figures Figure 1 1 IMB M43 Motherboard 5 Figure 1 2 IMB M43 I O Panel 7 Figure 1 3 LAN Port LED Indicators 8 ...

Page 10: ...x List of Figures This page intentionally left blank ...

Page 11: ...Tables xi IMB M43 List of Tables Table 1 1 IMB M43 Motherboard Legend 6 Table 1 2 IMB M43 I O Legend 7 Table 1 3 COM Port Pin Definitions 8 Table 1 4 LAN Port LED Legend 8 Table A 1 Navigation Key Functions 32 ...

Page 12: ...xii List of Tables This page intentionally left blank ...

Page 13: ...splayPort supporting up to 3 independent displays X 6x COM ports pin headers 2x rear 4x onboard pin head ers COM1 2 supporting RS232 422 485 RS 485 w auto flow control X Watchdog Timer Hardware Monitor X 1x 10 pin 2 54mm GPIO pin header 4 in 4 out one ground pin and one power pin 5V 12V no power jumper selected X 1x 25 pin 2 54mm printer port pin header X 1x Mini DIN for PS 2 keyboard mouse X RoHS...

Page 14: ... 4T X Intel Pentium G4400 3 3GHz 3M Cache 14nm 54W TDP LGA1151 2C 2T X Intel Pentium G4400TE 2 4GHz 3M Cache 14nm 35W TDP LGA1151 2C 2T X Intel Celeron G3900 2 8GHz 2M Cache 14nm 65W TDP LGA1151 2C 2T X Intel Celeron G3900TE 2 6GHz 2M Cache 14nm 35W TDP LGA1151 2C 2T Chipset Intel Q170 Express Memory 4x 288 pin DDR4 sockets vertical Dual channel DDR4 2133 MHz up to 64GB BIOS AMI UEFI BIOS 128 Mbit...

Page 15: ...ers Expansion Slots Signal X If PEG3 is occupied PEG1 is PCIex8 Gen3 PEG2 is PCIex4 Gen3 and PEG3 is PCIex4 Gen3 X If PEG3 is not occupied and PEG2 is occupied PEG1 is PCIex8 Gen3 PEG2 is PCIex8 Gen3 and PEG3 is no signal X If PEG3 is not occupied and PEG2 is not occu pied PEG1 is PCIex16 Gen3 PEG2 and PEG3 is no signal X PCIe1 PCIe x4 Gen3 PCIe2 PCIe x4 Gen3 PCI1 PCI 2 2 PCI2 PCI 2 2 Physical Slo...

Page 16: ...CPU VGA 1 VGA connector rear resolution up to 1920 x 1200 60Hz DisplayPort 1 2 2 DP connector rear resolution up to 4096x2304 60Hz Ethernet Controller LAN1 Intel I219 LM via RJ45 connector rear LAN2 Intel I211 AT via RJ45 connector rear Intel AMT LAN1 Support Wake On LAN LAN1 and LAN2 support Mechanical and Environmental Form Factor ATX Dimensions 305 mm x 244 mm WxL Operating Temperature 0 C to 6...

Page 17: ... connector B FAN1 4 pin CPU FAN connector C SATA3 4 Upper SATA3 Lower SATA4 D SATA1 2 Upper SATA1 Lower SATA2 E SATA5 6 Upper SATA5 Lower SATA6 F FAN3 4 pin system FAN2 connector G CN23 Digital I O pin header H CN22 GPI O port power select A B C E D F G H I J K L M N O P Q R S T U V W X Y Z AA BB CC DD EE ...

Page 18: ...7 8 USB2 0 port 5 6 O CN37 Printer port header P COM6 Serial port 6 Q COM5 Serial port 5 R COM4 Serial port 4 S COM3 Serial port 3 T PCI2 PCI connector U PCIe2 PCIe x4 connector V PCIe1 PCIe x4 connector W PEG3 PCIe x4 connector X PEG2 PCIe x16 connector Y PCI1 PCI connector Z PEG1 PCIe x16 connector AA CN31 Serial port 3 power select BB CN32 Serial port 4 power select CC CN35 Serial port 5 power ...

Page 19: ...h COM ports configurable in BIOS setup A VGA J USB3 0 4 USB2 0 4 B COM1 K USB3 0 1 USB2 0 1 C PS2 Combo L USB3 0 2 USB2 0 2 D LAN1 M USB3 0 5 USB2 0 11 E LAN2 N USB3 0 6 USB2 0 12 F Line In O COM2 G Line Out P DP2 H Mic In Q DP1 I USB3 0 3 USB2 0 3 Pin RS232 RS422 RS485 1 DCD Data Carrier Detect TX Data 2 RXD Receive Data TX Data 3 TXD Transmit Data RX N A A B C D E F G H I J K L M N O P Q ...

Page 20: ... Port LED Indicators Table 1 4 LAN Port LED Legend 4 DTR Data Terminal Ready RX N A 5 GND GND GND 6 DSR Data Set Ready N A N A 7 RTS Request To Send N A N A 8 CTS Clear To Send N A N A 9 RI Ring Pin N A N A ACT LINK Off No Link Blinking Transmission Underway Lit Link SPEED Off 10 Mb s Green 100 Mb s Orange 1 Gb s Pin RS232 RS422 RS485 ACT LINK SPEED ...

Page 21: ...aders and connectors may cause permanent damage Pin Name 1 P_ 3V3_PSU 2 P_ 3V3_PSU 3 GND 4 P_ 5V_PSU 5 GND 6 P_ 5V_PSU 7 GND 8 PSU_PWROK 9 P_ 5VSB_PSU 10 P_ 12V_PSU_CN 11 P_ 12V_PSU_CN 12 P_ 3V3_PSU 13 P_ 3V3_PSU 14 P_N12V_PSU 15 GND 16 PS_ON L 17 GND 18 GND 19 GND 20 PS_TP1 Test pad 21 P_ 5V_PSU 22 P_ 5V_PSU 23 P_ 5V_PSU 24 GND 1 12 24 13 ...

Page 22: ...tion 1 5 2 CN44 System Panel Header 1 5 3 COM3 Serial Port Header Pin Name 1 CN_HDLED 2 CN_PLED 3 CN_HDLED 4 CN_PLED 5 GND 6 CN_PWRBTN L 7 CN_RESETBTN L 8 GND 9 NC 10 NC Pin Name 1 CN_COM C_DCD L 1 2 9 10 1 2 8 9 ...

Page 23: ... CN_COM C_RX 4 CN_COM C_RTS L 5 CN_COM C_TX 6 CN_COM C_CTS L 7 CN_COM C_DTR L 8 CN_COM C_POWER 9 GND 10 NC Pin Name 1 CN_COM D_DCD L 2 CN_COM D_DSR L 3 CN_COM D_RX 4 CN_COM D_RTS L 5 CN_COM D_TX 6 CN_COM D_CTS L 7 CN_COM D_DTR L 8 CN_COM D_POWER 9 GND 10 NC Pin Name 1 2 8 9 ...

Page 24: ... Port Header 1 5 6 COM6 Serial Port Header Pin Name 1 CN_COM E_DCD L 2 CN_COM E_DSR L 3 CN_COM E_RX 4 CN_COM E_RTS L 5 CN_COM E_TX 6 CN_COM E_CTS L 7 CN_COM E_DTR L 8 CN_COM E_POWER 9 GND 10 NC Pin Name 1 CN_COM F_DCD L 1 2 8 9 1 2 8 9 ...

Page 25: ... CN16 USB3 0 Header 2 CN_COM F_DSR L 3 CN_COM F_RX 4 CN_COM F_RTS L 5 CN_COM F_TX 6 CN_COM F_CTS L 7 CN_COM F_DTR L 8 CN_COM F_POWER 9 GND 10 NC Pin Name 1 P_ 5V_USB_VBUS_P9 2 CN_U3_USB3_RXN_7 3 CN_U3_USB3_RXP_7 4 GND Pin Name 1 20 ...

Page 26: ...B2N_5 9 CN_U2_USB2P_5 10 NC 11 CN_U2_USB2P_6 12 CN_U2_USB2N_6 13 GND 14 CN_U3_USB3_TXP_8 15 CN_U3_USB3_TXN_8 16 GND 17 CN_U3_USB3_RXP_8 18 CN_U3_USB3_RXN_8 19 P_ 5V_USB_VBUS_P10 20 NC Pin Name 1 P_ 5V_USB_VBUS_P6 2 P_ 5V_USB_VBUS_P5 3 CN_U2_USB2N_7 4 CN_U2_USB2N_8 5 CN_U2_USB2P_7 Pin Name 1 10 2 ...

Page 27: ... USB2 0 Header 1 5 10 CN38 Front Audio Header 6 CN_U2_USB2P_8 7 GND 8 GND 9 X 10 NC Pin Name 1 P_ 5V_USB_VBUS_P7 2 P_ 5V_USB_VBUS_P8 3 CN_U2_USB2N_9 4 CN_U2_USB2N_10 5 CN_U2_USB2P_9 6 CN_U2_USB2P_10 7 GND 8 GND 9 X 10 NC Pin Name 1 10 2 ...

Page 28: ...16 Introduction Pin Name 1 A_MIC2_IN_L 2 GND_AUD 3 A_MIC2_IN_R 4 CN_FP_PRES L 5 A_L_OUT2_R 6 CN_SRTN1 7 A_HP2_JD 8 NC 9 A_L_OUT2_L 10 CN_SRTN2 1 2 9 10 ...

Page 29: ...System FAN1 Connector Pin Name Note 1 GND GND 2 P_ 12V_PSU FAN Power 3 O_CPUFAN_IN BMC_FAN_IN_CPU FAN TACHO 4 O_CPUFAN_OUT BMC_FAN_OUT_CPU FAN PWM IN Pin Name Note 1 GND GND 2 P_ 12V_PSU FAN Power 3 O_SYSFAN_IN0 BMC_FAN_IN FAN TACHO 4 O_SYSFAN_OUT0 BMC_FAN_OUT FAN PWM IN 1 4 1 4 ...

Page 30: ...Connector 1 5 14 CN54 LAN1 LED Indicator Pin Name Note 1 GND GND 2 P_ 12V_PSU FAN Power 3 O_SYSFAN_IN1 BMC_FAN_IN1 FAN TACHO 4 O_SYSFAN_OUT1 BMC_FAN_OUT1 FAN PWM IN LAN1 Link with Activity LED Header 1 P_ 3V3_LAN_A 2 L_i219_LED0_LINK ACT L 1 4 2 1 ...

Page 31: ...Introduction 19 IMB M43 1 5 15 CN53 LAN2 LED Indicator 1 5 16 PS2 Combo Connector LAN1 Link with Activity LED Header 1 P_ 3V3_LAN_A 2 L_i210_LED1_LINK ACT L Pin Name Note 1 O_KBDATA 2 O_MSDATA 3 GND 2 1 ...

Page 32: ...DUAL 5 O_KBCLK 6 O_MSCLK Pin Name 1 O_STB L_CON 2 O_AFD L_CON 3 O_PD0_CON 4 O_ERR L_CON 5 O_PD1_CON 6 O_INIT L_CON 7 O_PD2_CON 8 O_SLIN L_CON 9 O_PD3_CON 10 GND 11 O_PD4_CON 12 GND 13 O_PD5_CON 14 GND 15 O_PD6_CON 16 GND 17 O_PD7_CON 18 GND 19 O_ACK L_CON 20 GND Pin Name Note ...

Page 33: ...Introduction 21 IMB M43 21 O_BUSY_CON 22 GND 23 O_PE_CON 24 GND 25 O_SLCT_CON 26 NC Pin Name ...

Page 34: ...22 Introduction ...

Page 35: ...X The IMB M43 must be protected from static dis charge and physical shock Never remove any of the socketed parts except at a static free work station X Ensure the power supply is disconnected before installing or removing the motherboard to avoid physical injury and device damage X To avoid damage from static electricity never place the motherboard directly on carpet or similar surfaces X Wear a g...

Page 36: ...mory module 1 Locate the DIMM slots on the motherboard CAUTION Avoid over tightening screws to prevent PCB damage NOTE NOTE X Dual channel configuration requires installation of DDR4 DIMM pairs of identical brand speed size and chip type X Dual Channel Memory technology is disabled when only one memory module is installed CAUTION X DDR DDR2 or DDR3 memory modules cannot be installed in a DDR4 slot...

Page 37: ...retaining clips outward to unlock 3 Align the memory module on the socket making sure that the module notch matches the slot rail 4 Insert the module firmly into the slot until the retaining clips snap back inwards and the module is securely seated ...

Page 38: ... inter face X If PEG3 is occupied PEG1 is PCIex8 Gen3 PEG2 is PCIex4 Gen3 and PEG3 is PCIex4 Gen3 X If PEG3 is not occupied and PEG2 is occupied PEG1 is PCIex8 Gen3 PEG2 is PCIex8 Gen3 and PEG3 is no sig nal X If PEG3 is not occupied and PEG2 is not occupied PEG1 is PCIex16 Gen3 PEG2 and PEG3 is no signal X PCIe1 PCIe x4 Gen3 X PCIe2 PCIe x4 Gen3 ...

Page 39: ...nstallation 1 Remove the system unit cover if the motherboard is installed in a chassis 2 Remove the bracket facing the destination slot 3 Align the card connector with the slot and press firmly until the card is securely seated 4 Fix the card to the chassis with screws 5 Replace the system cover 2 5 Jumper Settings CN24 NOTE NOTE denotes default setting 1 2 2 3 Clear CMOS 1 2 Normal 2 3 Clear CMO...

Page 40: ... ME GPIO Port Power Select N A No Power 1 2 P_ 5V_PSU 2 3 P_ 12V_PSU Serial Port 3 Power Select N A No Power 1 2 P_ 5V_PSU 2 3 P_ 12V_PSU Serial Port 4 Power Select N A No Power 1 2 P_ 5V_PSU 2 3 P_ 12V_PSU Serial Port 5 Power Select N A No Power 1 2 P_ 5V_PSU 2 3 P_ 12V_PSU ...

Page 41: ...ng Started 29 IMB M43 CN36 2 6 Driver Installation Download the requisite drivers for your system from http www adlinktech com and install Serial Port 6 Power Select N A No Power 1 2 P_ 5V_PSU 2 3 P_ 12V_PSU ...

Page 42: ...30 Getting Started This page intentionally left blank ...

Page 43: ...m chassis A 2 UEFI Menu Bar The top of the screen has a menu bar with the following selec tions Use arrow keys to choose among the selections on the menu bar and select Enter to access the sub screen The mouse can also be used to select items NOTE NOTE Because the UEFI software is frequently updated the setup screens and descriptions provided are for reference only and may not conform exactly with...

Page 44: ...view Key s Function R L Arrow Moves cursor left or right to select Menus U D Arrow Moves cursor up or down to select items Changes option for the selected item Enter Opens the selected Menu F1 Displays General Help F2 Previous values F3 Optimized default values for all settings F4 Saves changes and exits Setup ESC Opens the Exit Menu or exits the current screen ...

Page 45: ...UEFI Setup Utility 33 IMB M43 A 5 Advanced Menu ...

Page 46: ... Enable Hibernation Enables or Disables System ability to hibernate OS S4 Sleep State This option may be not effective with some OS ACPI Sleep State Selects the highest ACPI sleep state the system will enter when the SUSPEND button is pressed ...

Page 47: ...UEFI Setup Utility 35 IMB M43 A 5 2 CPU Configuration ...

Page 48: ... HT Technology When Disabled only one thread per enabled core is enabled Active Processor Cores Number of cores to enable in each processor package Intel Virtualization Technology When enabled utilizes the additional hardware capabilities pro vided by Vanderpool Technology CPU AES Enables disables CPU Advanced Encryption Standard instructions ...

Page 49: ...C states CState Pre Wake Disable Sets bit 30 of POWER_CTL MSR 0x1FC to 1 to disable the Cstate Pre Wake Package C State limit Options C0 C1 C2 C3 C6 C7 C7s C8 AUTO CPU DTS Disabled ACPI thermal management uses EC reported tempera ture values Enabled ACPI thermal management uses DTS SMM mechanism to obtain CPU temperature values Out of Spec ACPI Thermal Management uses EC reported tem perature valu...

Page 50: ... UEFI Setup Utility ACPI 3 0 T States Enables disables ACPI 3 0 T States Intel TXT LT Support Disables Intel TXT LT support A 5 3 Chipset Configuration Memory Remap Enables disables Memory Remap above 4GB ...

Page 51: ... IMB M43 A 5 4 System Agent SA Configuration VT d VT d capability Above 4GB MMIO BIOS assignment Enables disables above 4GB MemoryMapped IO BIOS assign ment This is disabled automatically when Aperture Size is set to 2048MB ...

Page 52: ...aphics Configuration Primary Display Selects which IGFX PEG PCI Graphics device should be Primary Display Or selects SG for Switchable Gfx Internal Graphics Keep IGFX enabled based on the setup options GTT Size Selects the GTT Size ...

Page 53: ...aphics Memory size used by the Internal Graphics Device DVMT Total Gfx Mem Selects DVMT5 0 Total Graphic Memory size used by the Internal Graphics Device A 5 6 PCI Express Configuration NOTE NOTE Above 4GB MMIO BIOS assignment is automatically enabled when selecting 2048MB aperture To use this feature please disable CSM Support ...

Page 54: ... Configuration PEG Port Options Max Link Speed Configure PEG1 Max Speed Option Auto Gen1 Gen2 Gen3 Max Link Speed Configure PEG2 Max Speed Option Auto Gen1 Gen2 Gen3 Max Link Speed Configure PEG3 Max Speed Option Auto Gen1 Gen2 Gen3 ...

Page 55: ...ity 43 IMB M43 PCIE1 PCIe Speed Selects PCI Express port speed Options Auto Gen1 Gen2 Gen3 Detect Non Compliance Device Options Disabled Enabled Detects Non Compliance PCI Express Device If enabled increases POST time ...

Page 56: ...up Utility PCIE2 PCIe Speed Selects PCI Express port speed Options Auto Gen1 Gen2 Gen3 Detect Non Compliance Device Options Disabled Enabled Detects Non Compliance PCI Express Device If enabled increases POST time ...

Page 57: ...UEFI Setup Utility 45 IMB M43 A 5 7 USB Configuration ...

Page 58: ...st controller and root ports for faster enumeration USB3 Port 1 USB3 Port 8 Enables disables USB port USB2 Port 1 USB2 Port 14 Enables disables USB port Legacy USB Support Enables Legacy USB support AUTO option disables legacy support if no USB devices are con nected ...

Page 59: ...should be enabled for complete USB keyboard legacy support for non USB aware OSes USB transfer time out The time out value for Control Bulk and Interrupt transfers Options 1 sec 5 sec 10 sec 20 sec Device reset time out USB mass storage device Start Unit command time out Options 10 sec 20 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to...

Page 60: ...ode Legacy USB Support Selects legacy support for USB devices from default Enabled supporting legacy USB Auto supporting legacy USB when devices are connected and Disabled if USB compatibility issues occur it is recommended to select Disabled to enter OS and UEFI Setup Only in which USB devices are allowed only under UEFI setup and Windows Linux OS ...

Page 61: ...cy support for USB 3 0 devices with default Enabled A 5 9 HD Audio Configuration HD Audio Control Detection of the HD Audio device Disabled HDA will be unconditionally disabled Enabled HDA will be unconditionally enabled Auto HDA will be enabled if present disabled otherwise ...

Page 62: ...bles disables SATA Device SATA Mode Selection Determines how SATA controller s operate Options AHCI RAID Aggressive LPM Support Enable PCH to aggressively enter link power state SATA Controller Speed Indicates the maximum speed the SATA controller can support Options Default Gen1 Gen2 Gen3 ...

Page 63: ...UEFI Setup Utility 51 IMB M43 Port 1 Port 6 Enables or Disables SATA Port A 5 11 Onboard Device Configuration ...

Page 64: ... Serial Port COM COM1 Control Selects COM1 mode RS232 RS422 or RS485 Serial Port 2 Enables or Disables Serial Port COM COM2 Control Selects COM2 mode RS232 RS422 or RS485 Serial Port 3 6 Enables or Disables Serial Port COM This page intentionally left blank ...

Page 65: ...CI Bus0 Dev22 Func3 Parallel Port Enables or Disables Parallel Port LPT LPTE Device Mode Change the Printer Port mode Option STD Printer Mode SPP Mode EPP 1 9 and SPP Mode EPP 1 7 and SPP Mode ECP Mode ECP and EPP 1 9 Mode ECP and EPP 1 7 Mode LAN 1 Intel I219 Enables disables LAN 1 I219 Launch PXE OpROM Enables disables Boot Option for Legacy Network Devices LAN 2 Intel I211 Enables disables LAN ...

Page 66: ...ut down NOTE AT mode will not support S3 S4 State After G3 Specify what state to go to when power is re applied after a power failure G3 state Options Power On Power Off Last State RTC Wake system from S5 Enables disables System wake on alarm event Selects FixedTime system will wake on the hr min sec specified ...

Page 67: ...les disables PCI Express Slot wake capability Onboard LAN i219 Wake Enables disables onboard LAN wake capability PCI SIO Wake Enables disables PCI SIO wake capability PS 2 Device Wake Enables disables PS 2 device wake from S5 BIOS POST Watchdog Set watchdog timer for BIOS POST process Options Disabled Second Mode Minute Mode ...

Page 68: ...es Intel Active Management Technology BIOS Extension Note iAMT H W is always enabled This option just controls the BIOS extension execution If enabled this requires additional firm ware in the SPI device BIOS Hotkey Pressed OEMFLag Bit 1 Enables disables BIOS hotkey press ...

Page 69: ...UEFI Setup Utility 57 IMB M43 A 5 14 Intel BIOS Guard Technology Intel Bios Guard Support Enables disables Intel BIOS Guard Support Disable before flash ing BIOS ...

Page 70: ...58 UEFI Setup Utility A 5 15 Network Stack Configuration Network Stack Enables disables UEFI Network Stack ...

Page 71: ...les disables CSM Support GateA20 Active UPON REQUEST GA20 can be disabled using BIOS services ALWAYS do not allow disabling GA20 this option is useful when any RT code is executed above 1MB Option ROM Messages Set display mode for Option ROM Options Force BIOS Keep Current ...

Page 72: ...legacy boot Boot option filter This option controls Legacy UEFI ROMs priority Network Controls the execution of UEFI and Legacy PXE OpROM Storage Controls the execution of UEFI and Legacy Storage OpROM Video Controls the execution of UEFI and Legacy Video OpROM Other PCI devices Determines OpROM execution policy for devices other than Net work Storage or Video ...

Page 73: ...UEFI Setup Utility 61 IMB M43 A 5 17 NCT6106D HW Monitor ...

Page 74: ...Fan Control Mode Select Options Manual Mode SMART FAN IV T1 T1 Temperature 1 Range 1 100 T1 Duty Set T1 related DC PWM value Range 0 255 T2 T2 Temperature 2 Range 1 100 T2 Duty Set T2 related DC PWM value Range 0 255 T3 T3 Temperature 3 Range 1 100 ...

Page 75: ...1 Control Mode System Fan1 Control Mode Select Options Manual Mode SMART FAN IV T1 T1 Temperature 1 Range 1 100 T1 Duty Set T1 related DC PWM value Range 0 255 T2 T2 Temperature 2 Range 1 100 T2 Duty Set T2 related DC PWM value Range 0 255 T3 T3 Temperature 3 Range 1 100 T3 Duty Set T3 related DC PWM value Range 0 255 T4 T4 Temperature 4 Range 1 100 T4 Duty Set T4 related DC PWM value Range 0 255 ...

Page 76: ...T1 Temperature 1 Range 1 100 T1 Duty Set T1 related DC PWM value Range 0 255 T2 T2 Temperature 2 Range 1 100 T2 Duty Set T2 related DC PWM value Range 0 255 T3 T3 Temperature 3 Range 1 100 T3 Duty Set T3 related DC PWM value Range 0 255 T4 T4 Temperature 4 Range 1 100 T4 Duty Set T4 related DC PWM value Range 0 255 Critical Critical Temperature ...

Page 77: ...n Timer Enables disables the High Precision Event Timer Port 80h Redirection Control where the Port 80h cycles are sent Options LPC Bus PCIE Bus SMART Self Test Run SMART Self Test on all HDDs during POST Pcie Pll SSC Pcie Pll SSC percentage AUTO Keep hw default no BIOS override ...

Page 78: ...Range is 0 0 2 0 A 6 Security A 6 1 Administrator Password Administrator Password Set Administrator Password User Password Set User Password RTC Lock Enable will lock bytes 38h 3Fh in the lower upper 128 byte bank of RTC RAM ...

Page 79: ... 2 Secure Boot menu Secure Boot Secure Boot can be enabled if 1 System running in User mode with enrolled Platform Key PK 2 CSM function is disabled Secure Boot Mode Secure Boot mode selector Options Standard Custom Custom Mode enables users to change Image Execution policy and manage Secure Boot Keys ...

Page 80: ...users to modify Secure Boot variables A 7 Boot Setup Prompt Timeout Number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Bootup NumLock State Selects the keyboard NumLock state Quiet Boot Enables disables Quiet Boot option ...

Page 81: ...detected UEFI boot options Options Default Place First Place Last Boot mode select Selects boot mode LEGACY UEFI Boot Option 1 Sets the system boot order Boot Option 2 Sets the system boot order Boot Option 3 Sets the system boot order Boot Option 4 Sets the system boot order Boot Option 5 Sets the system boot order Boot Option 6 Sets the system boot order Boot Option 7 Sets the system boot order ...

Page 82: ...Exit Exit system setup after saving the changes Discard Changes and Exit Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes ...

Page 83: ...up options Restore Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Launch EFI Shell from filesystem device Attempts to Launch EFI Shell application Shell efi from one of the available filesystem devices ...

Page 84: ...72 UEFI Setup Utility This page intentionally left blank ...

Page 85: ...urn off power and unplug any power cords cables X To avoid electrical shock and or damage to equipment Z Keep equipment away from water or liquid sources Z Keep equipment away from high heat or high humidity Z Keep equipment properly ventilated do not block or cover ventilation openings Z Make sure to use recommended voltage and power source settings Z Always install and operate equipment near an ...

Page 86: ...viced by authorized technicians when Z The power cord or plug is damaged Z Liquid has penetrated the equipment Z It has been exposed to high humidity moisture Z It is not functioning or does not function according to the user s manual Z It has been dropped and or damaged and or Z It has an obvious sign of breakage WARNING Risk of explosion if battery is replaced with one of an incorrect type Dispo...

Page 87: ... 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology Beijing Address ҀᏖ ऎϞഄϰ䏃 1 োⲜ ࡼ ॺ E ᑻ 801 ᅸ 100085 Rm 801 Power Creative E No 1 Shang Di East Rd Beijing 100085 China Tel 86 10 5885 8666 Fax 86 10 5885 8626 Email market adlinktech com ADLINK Technology Shenzhen Address ഇᏖफቅऎ ᡔುफऎ催ᮄफϗ䘧 ᄫᡔᴃು A1 2 ὐ C ऎ 518057 2F C Block Bldg A1 Cyber Tech Zone Gao Xin Ave Sec 7 High Te...

Page 88: ...Korea Tel 82 2 2057 0565 Fax 82 2 2057 0563 Email korea adlinktech com ADLINK Technology Singapore Pte Ltd Address 84 Genting Lane 07 02A Cityneon Design Centre Singapore 349584 Tel 65 6844 2261 Fax 65 6844 2263 Email singapore adlinktech com ADLINK Technology Singapore Pte Ltd Indian Liaison Office Address 50 56 First Floor Spearhead Towers Margosa Main Road between 16th 17th Cross Malleswaram Ba...

Reviews: