5.1.4 Exception
Codes
In case of an error, the BMC drives a blinking code on the blue Status LED (LED1). The same error code is also reported by the BMC Flags
register. The Exception Code is not stored in the Flash Storage and is cleared when the power is removed. Therefore, a “Clear Exception
Code” command is not needed or supported.
Exception Code
Error Message
0 NOERROR
2 NO_SUSCLK
3 NO_SLP_S5
4 NO_SLP_S4
5 NO_SLP_S3
6 NO_CB_PWRGD
7 BIOS_FAIL
8 RESET_FAIL
9 RESETIN_FAIL
10 CRITICAL_TEMP
11
POWER FAIL
12 VOLTAGE_FAIL
13 NO_SYS_GD
14 NO_3V3_A_PGD
15 NO_VDDQ_PG
16 NO_P_5V_3V3_S0_PG
17 NO_1V0_A_PG
18 NO_VCORE_PG
19 MEMORY_ERROR
5.1.5 BMC
Flags
The BMC Flags register returns the last detected Exception Code since power-up and shows the BIOS in use and the power mode.
Bit
Description
[ 0 ~ 4 ]
Exception Code
[ 6 ]
0 = AT mode
1 = ATX mode
[ 7 ]
0 = Standard BIOS
1 = Fail-safe BIOS.