cExpress-BT2
Smart Embedded Management Agent (SEMA)
35
5.1.4.
Exception Codes
In case of an error, the BMC drives a blinking code on the blue Status LED (LED1). The same error code is also
reported by the BMC Flags register. The Exception Code is not stored in the Flash Storage and is cleared when the
power is removed. Therefore, a “Clear Exception Code” command is not needed or supported.
Exception Code
Error Message
0
NOERROR
2
NO_SUSCLK
3
NO_SLP_S5
4
NO_SLP_S4
5
NO_SLP_S3
6
BIOS_FAIL
7
RESET_FAIL
8
POWER_FAIL
9
LOW_VIN
10
VCORE
11
VGFX
12
V1P05S
13
VMEM
14
V1P0A
15
V3P3A
16
+P12V_5V
18
CRITICAL_TEMP
19
NO_CB_PWROK
20
NO_HW_PWORK
21
NO_V1P24A_PG
Table 8: SEMA Exception Codes
5.1.5.
BMC Flags
The BMC Flags register returns the last detected Exception Code since power-up and shows the BIOS in use and
the power mode.
Bit
Description
[ 0 ~ 4 ]
Exception Code
[ 6 ]
0 = AT mode
1 = ATX mode
[ 7 ]
0 = Standard BIOS
1 = Fail-safe BIOS.
Table 9: SEMA BMC Flags